Installation, Technical specifications – dc-400 – Lincoln Electric IDEALARC DC-400 User Manual

Page 8

Advertising
background image

A-1

INSTALLATION

IDEALARC® DC-400

A-1

TECHNICAL SPECIFICATIONS – DC-400

INPUT-THREE PHASE ONLY

RATED OUTPUT

HEIGHT

WIDTH

DEPTH

WEIGHT

27.50 in.

22.25 in.

32.0 in.

473 lbs.

699 mm

565 mm

988 mm

215 kg.

OUTPUT

RECOMMENDED INPUT WIRE AND FUSE SIzES FOR MAXIMUM RATED OUTPUT.

IN ADDITION, FOLLOW LATEST NATIONAL ELECTRICAL CODE AND LOCAL CODE.

Duty Cycle

(1)

Amps

Volts at Rated Amps

100%

400

36

60%

450

38

50%

500

40

PHYSICAL DIMENSIONS

(1) Based upon 10 minute time period (i.e., for 60% duty cycle, it is 6 minutes on an 4 minutes off).

*

Use only bussmann Super-Lag fuses specified. Other fuses may not protect the welder and may cause overheating and possible
fire damage.

Insulation class 155(F)

220/50/60Hz
230/50/60Hz
380/50/60Hz
400/50/60Hz
415/50/60Hz
440/50/60Hz

81
77
47
45
43
41

3(25)
3(25)
6(16)
6(16)
8(10)
8(10)

8(10)
8(10)
10(6)
10(6)
10(6)
10(6)

100 REN-100
100 REN-100

60 RES-60
60 RES-60
60 RES-60
50 RES-50

INPUT

VOLTAGE /

FREQUENCY

230/60Hz
460/60Hz
575/60Hz

INPUT AMPERE

RATING ON

NAMEPLATE

@100%

Duty Cycle

78
39
31

TYPE 75°C

COPPER WIRE IN

CONDUIT AWG

(IEC) SIZES (mm

2

)

40°C(104°F)

3(25)
8(10)
10(6)

TYPE 75°C

GROUND WIRE IN

CONDUIT AWG

(IEC) SIZES (mm

2

)

6(16)
10(6)
10(6)

BUSSMANN SUPER LAG

FUSE SIZE AND

CATALOG NUMBER

*

FUSE SIZE CATALOG NUMBER

100 REN-100

50 RES-50
40 RES-40

Standard

Voltage

Frequency

230/460/575V/60Hz

220/230/380/400/415/440V/50/60Hz

100% Duty Cycle

400Amps/36V

78/39/31Amps

400Amps/36V

81/77/47/45/43/41Amps

60% Duty Cycle

450Amps/38V

83/41/33Amps

450Amps/38V

85/81/49/47/45/42Amps

50% Duty Cycle

500Amps/40V

84/42/34Amps

500Amps/40V

86/82/50/48/46/43Amps

Input Current at Rated Output (CVI)

OUTPUT

MAXIMUM OPEN CIRCUIT VOLTAGE

AUXILIARY POWER

Min.----60A 12V CV(22V CC) 57V. (CC) 45.5V. (CVI) 60Hz

115 VAC, 15 AMPS

Max.---500A 42V (CC, CV)

54V. (CC) 45.5V. (CVI) 50/60 Hz

42 VAC, 10 AMPS

TEMPERATURE RANGES

OPERATING TEMPERATURE RANGE

-22°F to 104°F(-30°C +40°C)

STORAGE TEMPERATURE RANGE

-40°F to 140°F(-40°C+60°C)

Advertising