D-2

MAINTENANCE

D-2

MAGNUM® 450WC & 650WC

REMOVAL, INSTALLATION AND TRIMMING INSTRUCTIONS FOR LINERS

FITTING A HARD WIRE LINER FOR FEEDING SOLID AND CORED STEEL ELECTRODE

THE VARIATION IN CABLE LENGTHS
MAY PREVENT USE OF THE LINER
IN OTHER GUNS.

NOZZLE.

6. SECURE GAS DIFFUSER ONTO GUN TUBE AND REPLACE GAS

LINER BY TIGHTENING THE LINER NUT. DO NOT INSTALL THE
GAS DIFFUSER AT THIS TIME.

CUT OFF DIMENSION SHOWN AND REMOVE ANY BURRS.

5. LAY THE CABLE OUT STRAIGHT AND TRIM THE LINER TO THE

UNTRIMMED LINER INTO THE BACK END OF THE GUN.

4. SEAT LINER BUSHING INTO THE BACK OF THE GUN. SECURE

3. CHECK THE LINER FOR CORRECT WIRE SIZE AND INSERT AN

REMOVE THE LINER NUT FROM THE CONNECTOR END OF THE
CABLE, AND PULL LINER OUT OF THE CABLE.

2. LAY GUN AND CABLE OUT STRAIGHT ON A FLAT SURFACE,

THE GUN TUBE.

1. REMOVE THE GAS NOZZLE AND THE GAS DIFFUSER FROM

9/16"

(15MM)

INSTALLATION INSTRUCTIONS FOR LINERS DESIGNED
FOR FEEDING SOLID AND CORED STEEL WIRE

LINER NUT

KP44-3545-15

KP1933-3 5/64 (2.0mm)

.035-.045 (0.9-1.2mm)

KP-44-116-15 1/16 (1.6mm)

KP44-564-15

LINER

KP-44-116-15

WIRE SIZE

1/16-5/64 (1.6-2.0mm)

.052-1/16 (1.3-1.6mm)

KP44-3545-15 .045 (1.2MM)

STENCIL ON LINER BUSHING

COLOR

450WC

450WC

450WC

GUN