INSTALLATION

See Pipe Manufacturers Instructions For Installation Requirements Of Venting Components And Vent Clearances.

PAGE 12

RESIDENTIAL STANDARD

Using 6” (152 mm) Diameter Single Wall

Connector Pipe. Not Approved For

Manufactured (Mobile) Homes.

MANUFACTURED (MOBILE) HOME STANDARD

Using 6” (152 mm) Diameter Type L-Vent Connector Pipe



IMPORTANT NOTES:
Minimize the use of elbows (30°, 45° or 90°) - Offsets in the

venting system are very restrictive and will inhibit the draft
(i.e. You will lose approximately 5 feet of effective draft for
every 90 degrees of direction change). This appliance re-
quires 12 to 15 feet of effective draft for optimum perform-
ance (see Draft Requirements
on page 11).

First section of pipe must be vertical - Use as much straight
vertical pipe directly above the appliance as possible be-
fore using an elbow (a 2’ to 3’ initial vertical rise is sug-
gested).

Chimney
Termination Cap

Storm
Collar

Roof
Flashing

Ceiling Support
Assembly

Slip Adapter

Chimney
Connector

6” x 24”
24-Gage
Single Wall Pipe

5 ¼” (134 mm)

Floor
Protection

Square, Outside
Air Floor Duct

7 ft. (214 cm)

Minimum

DVL Close
Clearance
Connector

Support Box

Minimum 12-
15 ft. (366-
458 cm) of
Flue to
Achieve a
Stable Draft

14.5”
(369 mm)

3 ft. (915 mm)
Minimum

Spark Arrestor Cap

Storm Collar

Flashing