Installation Manual 11

ENGLISH

Installation

Indoor unit

1. Do not have any heat or steam near the unit.

2. Select a place where there are no obstacles

in front of the unit.

3. Make sure that condensation drainage can be

conveniently routed away.

4. Do not install near a doorway.

5. Ensure that the interval between a wall and

the left (or right) of the unit is more than
10cm(3.9in). The unit should be installed as
high as possible on the wall, allowing a
minimum of 20cm(7.9in) from ceiling.

6. Use a stud finder to locate studs to prevent

unnecessary damage to the wall.

Outdoor unit

1. If an awning is built over the unit to prevent

direct sunlight or rain exposure, make sure
that heat radiation from the condenser is not
restricted.

2. Ensure that the space around the back and

sides is more than 30cm(11.8in). The front of
the unit should have more than 70cm(27.6in)
of space.

3. Do not place animals and plants in the path

of the warm air.

4. Take the weight of the air conditioner into

account and select a place where noise and
vibration are minimum.

5. Select a place where the warm air and noise

from the air conditioner do not disturb
neighbors.

Select the best Location

More than
20cm(7.9in)

More than

10cm(3.9in)

More than
2.3m(7.6ft)

More than
10cm(3.9in)

More than
30cm(11.8in)

More than
30cm(11.8in)

More than
60cm(23.6in)

More than 60cm(23.6in)

More than
70cm(27.6in)

Install the indoor unit on the wall where the height from the floor is more than 2.3 meters(7.6ft).
A minimum pipe run of 7.5 meters(24.6ft) is required to minimize vibration & excessive noise