22 Room Air Conditioner

Installation

Outdoor

1. Remove the cover control from the unit by

loosening the screw.
Connect the wires to the terminals on the
control board individually as the following.

2. Secure the cable onto the control board with

the holder (clamper).

3. Refix the cover control to the original position

with the screw.

1. Separately wire power supply cord and connecting cable.

2. Use heat-proof electrical wiring capable of withstanding temperature up to 75°C(167°F).

3. Use outdoor and waterproof connection cable rated more than 300V for the connection between

indoor and outdoor unit. (For example, Type SJO-WA)

• Be sure to comply with local codes while running the wire from the indoor unit to the outdoor

unit(size of wire and wiring method, etc).

• Every wire must be connected firmly.
• No wire should be allowed to touch refrigerant tubing, the compressor or any moving parts.

NOTICE

Outdoor unit

Terminal block

Over 5mm

(0.2")

Cover control

Conduit panel

Connecting

cable

Power supply

cord

Wiring Diagram