Maintenance, Safety precautions, Warning routine maintenance – Lincoln Electric MULTI-SOURCE IM692 User Manual

Page 13: Periodic maintenance, Machine calibration specification

Advertising
background image

D-1

MAINTENANCE

D-1

MULTI-SOURCE

SAFETY PRECAUTIONS

Have qualified personnel do the maintenance
work. Always use the greatest care when
working near moving parts.

If a problem cannot be corrected by following
the instructions, take the machine to the nearest
Lincoln Field Service Shop.

-----------------------------------------------------------------------

ELECTRIC SHOCK can kill.

• Do not touch electrically live parts or

electrode with skin or wet clothing.

• Insulate yourself from work and

ground.

• Always wear dry insulating gloves.

--------------------------------------------------------------------

EXPLODING PARTS can cause injury.

• Failed parts can explode or cause other

parts to explode when power is
applied.

• Always wear a face shield and long sleeves

when servicing.

-------------------------------------------------------------------

See additional warning information
throughout this operator’s manual.

----------------------------------------------------------

WARNING

ROUTINE MAINTENANCE

The Multi-Source needs no routine maintenance. The
fan bearings are sealed units.

PERIODIC MAINTENANCE

Periodically the machine may be cleaned with low
pressure compressed air to insure that all cooling pas-
sages are open and that conductive foreign material
has not built up inside.

MACHINE CALIBRATION
SPECIFICATION

The Multi-Source digital display is controlled by a cur-
rent sensing circuit on the Control board. The display
reads 100 when machine output is a little over 40 kW.
To recalibrate the display, the machine output may
loaded with Multi-Weld welders or resistive grids or a
combination of both to obtain an output of 533 Adc as
read by a calibrated standard ammeter. Trimmer
resistor R49 may be adjusted to cause the display to
read 100.

Advertising