Troubleshooting, Caution – Lincoln Electric MULTI-SOURCE IM692 User Manual

Page 15

Advertising
background image

E-2

TROUBLESHOOTING

E-2

MULTI-SOURCE

Observe all Safety Guidelines detailed throughout this manual

If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely, contact your
Local Lincoln Authorized Field Service Facility for technical troubleshooting assistance before you proceed.

CAUTION

PROBLEMS

(SYMPTOMS)

POSSIBLE AREAS OF

MISADJUSTMENT(S)

RECOMMENDED

COURSE OF ACTION

Machine input contactor does not
operate.
(White Power light off)

(White Power light on)

Machine input contactor operates,
but no output when trying to weld.

Machine does not have maximum
output.

Machine has output only momentarily
after contactor closes.Output returns
momentarily every 75 seconds.

Machine has output only momen-
tarily, contactor opens immediately
after closing. (Green Safe Output
light off)

Machine output doesn’t stay on.
(Amber Thermal light on, fan run-
ning, digital Output display reads
greater than 100).

1. Supply line fuse is blown.
2. Contactor power circuit has an

open lead.

3. Broken power lead.
4. T2 internal thermal breaker open
5. Defective POWER ON/OFF

Switch (S1).

7. Control circuit diode bridge open
8. Transformer iron rear thermostat open.

1. Open input contactor coil.
2. Defective Control Board.
3. Contactor moving iron binding.

1. Electrode or work lead loose or

broken.

2. Open main transformer (T1) pri-

mary or secondary circuit.

3. Firing P.C. board not connected

or is faulty.

4. Firing board not getting enable

signal.

1. One input fuse blown.
2. One phase of main transformer

(T1) open.

3. Faulty Control or Firing P.C.

boards.

4. Faulty SCR bridge.
5. Input voltage too low.

1. Machine has either an internal or

external short circuit on the output.

2. Faulty Control PC board.

1. Output voltage peaks are too

high because input voltage too
high.

2. Output voltage peaks are too

high because output filter circuit
not working.

3. Output voltage peaks are too

high because control circuit isn’t
sensing output voltage.

4. Control board faulty.
5. Output SCR shorted.

1. Machine is overloaded.

If all recommended possible areas
of misadjustment have been
checked and the problem persists,
Contact your local Lincoln
Authorized Field Service Facility.