Troubleshooting & repair – Lincoln Electric INVERTEC POWER WAVE 450 SVM112-B User Manual

Page 160

Advertising
background image

Retur

n to Section TOC

Retur

n to Section TOC

Retur

n to Section TOC

Retur

n to Section TOC

Retur

n to Master TOC

Retur

n to Master TOC

Retur

n to Master TOC

Retur

n to Master TOC

F-100

F-100

INTERNAL AND AUXILIARY SUPPLY VOLTAGE TEST (continued)

TROUBLESHOOTING & REPAIR

13. With the Volt/ohmmeter, check the follow-

ing leads for continuity:

A. Between the Protection Board and Wire

Feeder 2 Receptacle:

Lead #32D

Between J34 - pin 5 and P82
- pin A

Lead #32E

Between J34 - pin 6 and P82
- pin I

Lead #42C

Between J34 - pin 3 and P82
- pin K

Lead #102D Between J34 - pin 4 and P82

- pin C

Lead #31C

Between J34 - pin 1 and P82
- pin J

Lead #106A Between J34 - pin 7 and P82

- pin D

B. Between the Protection Board and Wire

Feeder 1 Receptacle:

Lead #32B Between J34 - pin 12 and

P83 - pin A

Lead #32C Between J34 - pin 13 and

P83 - pin I

Lead #42B Between J34 - pin 10 and

P83 - pin K

Lead #102B Between J34 - pin 11 and

P83 - pin C

Lead #31B

Between J34 - pin 8 and P83
- pin J

Lead #105A Between J34 - pin 14 and

P83 - pin D

C. Between the protection board and the

square wave TIG protection board:

Lead #296

Between J38 - pin 3 and J92
- pin 6

14. After the test is completed and the prob-

lem successfully repaired, disconnect
input power to the machine.

15. Connect the five leads to main input con-

tactor CR1 and insert plug J30 into the
protection board.

16. Install the machine case sides and top.

17. Install the handle and the lift bail rubber

gasket.

POWER WAVE 450