20 Room Air Conditioner

Disassembly

11. Motor

1. Remove the cabinet. (Refer to section 2)

2. Remove the turbo fan. (Refer to section 4)

3. Remove the fan. (Refer to section 5)

4. Remove the 4 screws that fasten the motor from

the air guide. (See Figure 27)

5. Remove the motor.

6. Re-install the components by referring to the

removal procedure, above.(See Figure 27)

12. Condenser

CAUTION: Discharge the refrigerant
system using a Freon

TM

Recovery

System. If there is no valve to attach the
recovery system, install one (such as a
WATCO A-1) before venting the Freon

TM

.

Leave the valve in place after servicing
the system.

1. Remove the cabinet. (Refer to section 2)

2. Remove the 4 screws that fasten the

brace.(Refer to section 4)

3. Remove the 5 screws that fasten the condenser

and shroud.

4. After discharging the refrigerant completely,

unbraze the interconnecting tube at the con-
denser connections.

5. Remove the condenser.

6. Re-install the components by referring to notes.

(See Figure 28)

13. Evaporator

1. Remove the control box.(Refer to section 3)

2. Remove the air guide upper. (Refer to section 4)

3. Remove the 2 screws that fasten the evapora-

tor.

4. Move the evaporator sideways carefully.

(Refer to section 4)

5. After discharging the refrigerant completely,

unbraze the interconnecting tube at the evapo-
rator connections.

6. Remove the evaporator.

7. Re-install the components by referring to notes.

(See Figure 29)

Figure 27

Figure 28

Figure 29

Refrigerating Cycle