Troubleshooting, Caution – Lincoln Electric GX 271 User Manual

Page 43

Advertising
background image

GX 271 Chopper

E-4

TROUBLESHOOTING

E-4

Observe all Safety Guidelines detailed throughout this manual

If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely, contact your
Local Lincoln Authorized Field Service Facility for technical troubleshooting assistance before you proceed.

CAUTION

PROBLEMS

(SYMPTOMS)

POSSIBLE AREAS OF

MISADJUSTMENTS(S)

RECOMMENDED

COURSE OF ACTION

No welding power output.

Welder has output but no control.

No auxiliary power.

Wire feeder does not work when
connected to welder 14 pin amphe-
nol.

1. "Welding Terminals" switch in

wrong position.

2. Faulty welding alternator or faulty

PC board.

1. "Local/Remote" switch is in wrong

position.

2. Poor remote kit connection.
3. Faulty remote kit.
4. Faulty control potentiometer or

faulty PC board.

1. Open circuit breakers.

2. Faulty connections to auxiliary

receptacles.

3. GFCI tripped.

4. Faulty welding alternator or faulty

PC board.

1. Wire Feeder Power circuit breaker

open.

2. Faulty wiring in control cable
3. Faulty wire feeder.

1. Place switch in "Always On" position

when welding without welding terminal
control cable. Refer to Operation
chapter for proper switch function.

2. Contact your Local Lincoln Authorized

Field Service Facility for technical
troubleshooting assistance.

1. Place switch in "Control at Welder"

position to control output at welder.
Place switch in "Remote" position to
control output remotely. Refer to
Operation chapter for proper switch
function.

2. Check connections.
3. Replace if necessary.
4. Contact your Local Lincoln Authorized

Field Service Facility for technical
troubleshooting assistance.

1. Reset breakers. If breakers keep trip-

ping, reduce power draw.

2. Check connections.

3. Clear any ground fault and reset GFCI

circuit by pressing "Reset" button on
the 120 V receptacle.

4. Contact your Local Lincoln Authorized

Field Service Facility for technical
troubleshooting assistance.

1. Reset

2. Repair or replace cable
3. Replace with known good one.

Advertising