11

secondary readings are not achieved,

replace transformer.

Temperature display

If proper voltage is present at terminals

1,2, and 3 on temperature display, but

but the display is not lighted, recheck

all connections for tightness. If

temperature display is still not operating,

replace the temperature display.

Temperature display

Thermocouple

Connect the thermocouple of a

Inaccurate, erratic

pyrometer to the thermocouple on

Or inoperative

the temperature control board. (be sure

to maintain proper polarity of

thermocouple leads—see adjustment

section for proper procedure.) The

pyrometer will indicate oven temperature

display. Measure D.C. millivolts of

thermocouple at the temperature display.

See thermocouple chart in section D for

proper readings. Replace thermocouple

if proper readings are not achieved. If

readings are correct on the thermocouple,

replace temperature display.