Low Profile – 1600 Advantage Series Service Manual – International

6

TROUBLESHOOTING GUIDE

MODEL 1633-000 EA NATURAL GAS 230 VAC 50 HZ 1 PHASE

MODEL 1634-000-EA L.P. GAS 230 VAC 50 HZ 1 PHASE

NOTE: When checking components on left side of unit, be sure to check for proper

connections in power connector, ( marked P. C. on schematic diagram ) located inside

motor cover.

SYMPTOM

POSSIBLE CAUSE

EVALUATION

Oven fan will

Incoming power supply

Check breakers/ reset if required

not run

call Power company if needed

Oven fan switch

Check continuity between

switch terminals.

Thermostat, hi-limit

Terminals are normally closed, if

open, reset thermostat and test

oven for proper operation. If it

will not reset, replace thermostat.

Fan fuse

Check, replace if necessary.

Fuse holder

Check, replace if necessary.

Oven fan relay

Check for power to coil of oven

fan relay. If no voltage is present,

trace wiring back to hi-limit thermostat.

Check for supply voltage at terminal

#6 of the relay. If no voltage is present,

trace wiring back to fuse holder. If

voltage is present, at the relay coil, check

to insure the contacts are closing.

Capacitor(s)

Check for opens, shorts, or grounds.

Motor (s)

Check for opens, shorts, or grounds.

No control box cooling

Fan switch

(SEE OVEN

Hi-limit

FAN WILL

Oven fan relay

NOT RUN.)

Cooling fan(s)

Supply voltage should now be at these

motors. If voltage is present, check

motor for open, shorts, or grounds.

WITH POWER OFF: check for

locked rotor.

No automatic control

Incoming power supply

Check circuit breakers, reset if needed.

box cooling

Call power company if needed.

Cooling fan thermostats

Thermostat closes at 120

°

F and

opens at 100

°

F. With the cooling

fan thermostat preheated, check

for continuity. If switch is open, replace.

Cooling fan(s)

Supply voltage should now be at these

motors. If voltage is present, check

motor for opens, shorts or grounds.

WITH POWER OFF: Check for

locked rotor.

Oven will not heat

Gas supply

Check for adequate gas supply to oven.

Manual gas shut off valve

Check to see that the manual gas shut

off valve is open.

Fan switch

Check to see that the fan switch is on.

Main oven fan

Check if main oven fan is operating.

if not, refer to “oven fan will not run”.

NOTE: These ovens utilize 2 complete Burner/Temperature control systems. Each system will

Follow the same troubleshooting sequence.

Fuse, burner 3A.

Check, replace if necessary.