Operation, Controls and indicators, E figure 3-1 o – Lucent Technologies LULCST User Manual

Page 16: Operation 3-2, Controls and indicators 3-2, Operation controls and indicators

Advertising
background image

3-2

Operation

Operation

Controls and Indicators

Figure 3-1. Rear Panel Detail

Table 3-1. Rear Panel Description

ITEM DESCRIPTION

Power On LED Illuminates when power is supplied to the Call Stacker.

Pause Override Control
Input

Enables/disables the Page Output channel. When a contact
closure (a short) between the two terminals is detected, the
Call Stacker terminates the outgoing announcement (if any),
requeues it and disables the Page Output channel. When
the contact closure is removed, the Page Output channel is
re-enabled and the terminated announcement plays to the
paging system in its entirety (see note below).

Input Station
(record) Channels

PBX and KTS analog station interfaces (tip/ring pairs) to the
Public Telephone Network, a PABX or a Key System.

Page Output Channel

Audio and control contact signals to the paging system as
shown in figure 2-3. Between outgoing announcements the
control contact opens for a minimum of 250 msec. to release
the paging system controller.

Option Switch See

table 2-1.

Battery Switch

Enables/disables battery backup. Turn the switch ON to
enable the battery backup.

Power Input 110/120 VAC, 60Hz, power input

NOTE: The Input Station channels continue to operate when a contact closure is detected. Recorded
announcements are held in a queue and play out sequentially (first in, first out) when the contact
closure is removed.