Installation, Optional features installation, General panel installation guidelines – Lincoln Electric IM613-B User Manual

Page 19

Advertising
background image

A-11

INSTALLATION

POWER FEED 11

A-11

OPTIONAL FEATURES INSTALLATION

A number of Optional Features are available for

use with Power Feed 11. Some Installation informa-
tion is provided in this section, REFER TO THE
INSTRUCTIONS THAT COME WITH EACH KIT FOR
DETAILED INFORMATION REGARDING INSTALLA-
TION.

OPTIONAL PANELS FOR CONTROL BOX

All optional panels for the control box are described in
the ACCESSORIES section of this manual along with
their installation instructions as are all other pieces of
optional equipment.

The PF-11 Control Box is designed to accept two con-
trol panels and one door option. Panels can be
mounted in one of two positions: Upper and lower.

Each Control Box is shipped with a Control/Display
(CD) panel installed in the upper position, and a
CV/Gouge (CV/G) panel in the lower position.

The CD panel must be installed in every Control Box.
The remaining panel can be one of the following:
CV/G, MX2, or MSP2.

Note: The CD panel must be installed in the upper

position; its harness is not long enough to allow
installation in the lower position. Similarly,
option panels must be installed in the lower
position.

GENERAL PANEL INSTALLATION
GUIDELINES:

Installation or removal of any panel can be done with
only a Phillips screwdriver after the system power is
turned off. To remove a panel, remove the two screws
holding it in place, remove the push-on chassis
ground wire and remove the harness connection to
the Control Box main PC board. To install any panel,
reverse that process. Turn power back on when com-
plete (option panels are only recognized at power up.
Do not install panels with the power on.) Note that
removal or installation of any panel may also require
the removal of the other panel, in order to have easy
access to the PC board connectors. Detailed installa-
tion instructions are shipped with each option panel.