Operation, Wire drive operation – Lincoln Electric IM613-B User Manual

Page 25

Advertising
background image

B-6

OPERATION

B-6

WIRE DRIVE OPERATION

The most frequently used Wire Drive settings are
external; some features are accessed by internal set-
tings.

WIRE DRIVE SETTINGS -- EXTERNAL

2 STEP/4 STEP SWITCH:

The Wire Drive has a 2 Step/ 4 Step switch located
near the gun connector. This switch has no effect in
CC modes of operation, such as stick welding.

Europe and World 2 Step Logic:
1. Closing the gun trigger initiates the welding

sequence (preflow, run in, etc.).

2. Opening the gun trigger ends the welding

sequence (burnback, postflow, etc.).

World 4 Step Logic:
With Crater Fill “OFF”

1. Closing the gun trigger initiates the welding

sequence (preflow, run in, etc.).

2. Opening the trigger after the welding arc is estab-

lished allows the weld to continue as long as cur-
rent flows. If the arc goes out, the 4 step cycle is
reset.

3. Closing the trigger again allows the weld to contin-

ue.

4. Opening the trigger again ends the welding

sequence (burnback, postflow, etc.).

With Crater Fill “ON”

1. Closing the gun trigger initiates the welding

sequence (preflow, run in, etc.).

2. Opening the trigger after the welding arc is estab-

lished allows the weld to continue as long as cur-
rent flows. If the arc goes out, the 4 step cycle is
reset.

3. Closing the trigger again changes the wire feed

speed and the Volts/Trim to the Crater values,
and the weld to continues

4. Opening the trigger again ends the welding

sequence (burnback, postflow, etc.).

European Only 4 Step Logic
With Crater Fill “OFF”:

1. Closing the gun trigger initiates the welding

sequence (preflow, run in, etc.).

2. Opening the trigger allows the wire to continue

feeding before or after the welding arc is estab-
lished. If the arc goes out the wire continues feed-
ing.

3. Closing the trigger again cancels the interlock and

the wire to continues feeding.

4. Opening the trigger again ends the welding

sequence (burnback, postflow, etc.).

With Crater Fill “ON”:

1. Closing the gun trigger initiates the welding

sequence (preflow, run in, etc.).

2. Opening the trigger allows the wire to continue

feeding before or after the welding arc is estab-
lished. If the arc goes out the wire continues feed-
ing.

3. Closing the trigger again cancels the interlock

changes the wire feed speed and the Volts/Trim to
the Crater values, and the wire continues feeding.

4. Opening the trigger again ends the welding

sequence (burnback, postflow, etc.).

COLD FEED / GAS PURGE SWITCH:

The Wire Drive has a Cold Feed/Gas Purge Switch
located near the gun connector. This is an up/down
center-off momentary toggle switch.

When held in the up position, the Wire Drive will feed
wire, but neither the power source nor the gas sole-
noid will be energized. When cold feeding, the feed
speed can be adjusted by rotating the WFS encoder
knob on the Control Box. Adjusting the cold feed will
not affect the run in or welding wire feed speed.
When the cold feed switch is released, the cold feed
value is saved.

When this switch is held in the down position, the gas
solenoid valve is energized, but neither the power
source nor the drive motor will be energized.

POWER FEED 11