A-6

INSTALLATION

PRECISION TIG 375

A-6

TIG TORCH CONNECTION

The Precision TIG torch connection box, located on the

right side of the machine, provides all the input and

output connections for the installation of both air-

cooled and water-cooled TIG torches with fittings con-

forming to Compressed Gas Association (CGA) stan-

dards:

Note: The Precision TIG provides an insulated Torch

Reel and Holster for handy and safe storage of con-

nected torch when not welding, and excess torch cable

length while welding.

Combination

connectors

(Power/Water

and

Power/Gas) are electrically "hot" while welding in

STICK or TIG modes.

If using an Air-Cooled Torch be sure coolant is

shut off and/or Cooler is unplugged from the

Precision TIG Water Cooler Receptacle on the

torch side of the upper case back.

Observe the safety precautions necessary for han-

dling and using compressed gas containers.

Contact your supplier for specifics.

CYLINDER could explode

if damaged.

• Keep cylinder upright and

chained to a support.

• Keep cylinder away from areas

where it could be damaged.

• Never allow the torch to touch the cylinder.

• Keep cylinder away from live electrical cir-

cuits.

• Maximum inlet pressure 150 psi.

-----------------------------------------------------------------

The Precision TIG machines do not have Hi-Freq.

available at the Stick electrode stud, therefore stud

connection adapters (such as LECO. S19257-series)

cannot be used for torch connection.

Single-piece cable air-cooled torches with a 3/8-24 RH

connector fitting (such as the Magnum PTA-9/-17, or LA-

9/-17) require the provided S20403-4 Torch Connector,

while those with a 7/8-14 RH connector fitting (such as

the Magnum PTA-26, or LA-26) require the available

K2166-1 Torch Connector. (See Figure A.3)

Two-piece cable air-cooled torches (such as PTA-, or LA-

torches) can be used with the available K2166-2 1/2”

Stud Connector with with a 7/8-14 LH male fitting.

Magnum PTW-18/-20 (or LW-) water-cooled Torches

require no adapter for Precision TIG connection.

WARNING

WORK

STICK

WORK

STICK

STICK

ELECTRODE

STUD

WORK

STUD

TIG TORCH

CONNECTION

PANEL

FIGURE A

(Shown without hinged stud cover)

REMOTE

CONTROL

RECEPTACLE

CABLE

STRAIN

RELIEF HOLES

FIGURE A.2

Advertising