E-4

TROUBLESHOOTING

E-4

PRECISION TIG 375

Observe all Safety Guidelines detailed throughout this manual

If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely, contact your Local

Lincoln Authorized Field Service Facility for technical troubleshooting assistance before you proceed.

CAUTION

HI-FREQ PROBLEMS

PROBLEMS

(SYMPTOMS)

POSSIBLE AREAS OF

MISADJUSTMENTS

RECOMMENDED

COURSE OF ACTION

No hi-freq

Hi-freq intensity too weak

Hi-freq on continuously in DC Tig

Hi-freq shuts off after starting in AC

Tig

1. Circuit breaker CB1 open

2. Bad connection at P12 of Control

PC board

3. Spark gaps shorted

4. Faulty Control PC board

1. Dirty spark gap or improper gap

setting

2. Faulty Arc Starter assembly

1. Bad connection at P11 of Control

PC board

2. Micro-switch S2A is not engaged &

disengaged properly when switch-

ing between DC & AC polarity.

(S2A locates on the Polarity

switch)

3. Faulty Control PC board

1. Micro-switch S2A is not engaged &

disengaged properly when switch-

ing between DC & AC polarity.

(S2A locates on the Polarity

switch)

If all recommended possible areas

of

misadjustment

have

been

checked and the problem persists,

Contact

your

local

Lincoln

Authorized Field Service Facility.