Test procedures, Perform the rotor voltage test, Troubleshooting & repair – Lincoln Electric POWER-ARC 4000 SVM103-A User Manual

Page 51: Rotor voltage test, Warning

Advertising
background image

Return to Section TOC

Return to Section TOC

Return to Section TOC

Return to Section TOC

Return to Master TOC

Return to Master TOC

Return to Master TOC

Return to Master TOC

TROUBLESHOOTING & REPAIR

POWER-ARC 4000

F-10

ROTOR VOLTAGE TEST

Service and repair should be performed by only Lincoln Electric factory trained personnel.
Unauthorized repairs performed on this equipment may result in danger to the technician or
machine operator and will invalidate your factory warranty. For your safety and to avoid elec-
trical shock, please observe all safety notes and precautions detailed throughout this manu-
al.

If for any reason you do not understand the test procedures or are unable to perform the
test/repairs safely, contact the Lincoln Electric Service Department for electrical trou-
bleshooting assistance before you proceed. Call 216-383-2531 or 1-800—833-9353
(WELD).

TEST DESCRIPTION

This test will determine if the correct DC voltage is being applied to the rotor at maximum
engine speed (3700 RPM). This information will aid the technician in determining if the gen-
erator field is operating properly.

MATERIALS NEEDED

Volt/Ohmmeter
5/16” Nut driver
Wiring Diagram

WARNING

Advertising