Lennox Hearth VIS35 User Manual

Page 15

Advertising
background image

15

NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.

8’ Max.

Restrictor

Position # 4

Restrictor

Position # 3

Restrictor

Position # 3

Restrictor

Position # 2

No Restrictor

18” Section of Pipe

h

orizontal

t

erminations

The shaded areas in the diagram below show all allow-

able combinations of vent configurations with horizontal

terminations. Horizontal sections of pipe require 1/4” of

rise for every 12” of run. A second 90 degree or 45 degree

elbow (in addition to the first 90 degree elbow at the top of

the vertical length of pipe) is allowed as long as the overall

length of the horizontal run of pipe does not exceed those

shown below. Use the restrictor positions indicated. Note

that if the termination cap falls in the unshaded area below

then no restrictor is installed in the stove.

To install the stove with pipe directly out the back, a snorkel

is not required for the Vintage™ gas stove. A snorkel is re-

quired for the Vintage. See page 13 for snorkel installation

instructions.

v

ertiCal

t

erminations

The diagram below shows all allowable combinations of

straight vertical and offset to vertical vent configurations

with vertical terminations. The termination must fall within

the shaded areas on the diagram. Use the indicated restrictor

positions. Offsets may consist of two 90 degree elbows OR

four 45 degree elbows. The minimum termination height is

10’ and the maximum is 30’.

0 Feet

15 Feet

10 Feet

5 Feet

0 Feet

0 Feet

5 Feet

10 Feet

0 Feet

5 Feet

10 Feet

15 Feet

0 Feet

5 Feet

0 Feet

0 Feet

5 Feet

Figure 

Figure 7

Advertising
This manual is related to the following products: