Lennox Hearth VIS35 User Manual

Page 24

Advertising
background image

4

NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.

f

uel

C

onversion

Converting the stove between natural gas and LP can be ac-

complished by either changing the cassette (valve and pilot

assembly) or installing a conversion kit (regulator, burner

orifice, and pilot orifice). Only a qualified service technician

should perform the conversion.

Cassette Removal:

1. Be sure the gas supply is shut off and if the stove has an

optional blower installed the electrical supply is shut off

at the electrical panel before beginning the conversion.

Disconnect the gas supply from the stove, being careful

not to apply pressure to the valve in the process.

2. Remove the log set (see Baffle, Log Set, & Ember Instal-

lation).

3. Remove the allen head screw (A in Figure 38) at the left

end of the burner. Lift out the air control panel.

4. Pull the burner from the orifice and remove the wire

linkage connected to the burner air shutter.

5. Remove the labeled cover through which the valve

control knobs protrude by removing the two allen head

screws securing it and slide it off the valve knobs.

6. Mark and disconnect wires on valve terminals #1 and

#3 connected to the burner on/off switch, thermostat,

or remote control.

7. From inside the firebox, remove the two allen head

screws (screws C in Figure 37) and the bracket they

secure.

8. From inside the firebox, remove all four of the allen

head screws (B in Figure 37) fastening the cassette to

the firebox. The cassette is sealed to the stove using

high temperature cement. It may be necessary to cut

through this cement to remove the cassette.

9. Grasp the cassette assembly from below the firebox

and pull it away from the firebox.

10. Install new, converted, or serviced cassette in the reverse

order of removal. Apply a bead of high temperature

silicone prior to securing the cassette with the allen

head screws. All surfaces of cassette must be sealed

to the firebox to ensure an air tight seal.

11. All parts and wires must be correctly reinstalled to

ensure safe and proper operation of the unit.

A

Air Control Panel

Cassette Assembly

B

B

C

Conversion Kit

Please see instructions provided with conversion kit.

Figure 7

Figure 8

Advertising