Lathem PC100 User Manual

Page 12

Advertising
background image

PC100 Terminal User’s Guide

6

4. See the Cable Wiring Diagrams for detailed connection points

Connecting Terminals via RS-485 (Multi-Drop Configuration)

A multi-drop network connects up to 31 terminals or sync time devices to the
computer. You wire the terminals to junction boxes running in a single line
starting from the SWIFT-485+. Terminals can be located up to 4000 feet from
the computer




1. Run Category 3 (minimum) cable from the SWIFT-485+ to the first J-Kit

(junction box)

2. Use a cable (up to 4 feet long) with an RJ-11 connector on both ends, and

plug one end into the J-Kit (junction box)

3. Plug the other RJ-11 connector to a terminal

4. Connect the power cord (AC adapter) to the terminal and plug the cord

into a wall outlet

5. For the next terminal, run cable from the previous J-Kit (junction box) to

the next J-Kit (junction box) and repeat steps 2, 3 & 4

6. See the Cable Wiring Diagrams for detailed connection points

For more details or how to supply AC power to the PC100-R from the SWIFT-
485+, see the SWIFT-485+ User’s Guide.

Up to 31 Terminals

Max 4000 ft from SWIFT-485+ to Last Terminal

SWIFT-485+

J-Kit (junction box)

Advertising
This manual is related to the following products: