Lot series, Va s, Ingle – Lightolier LOT Series User Manual

Page 2: Hase

Advertising
background image

LOT Series

1.5-4.2

K

VA S

INGLE

P

HASE

UPS

Page 2 of 2

Philips Lightolier
e: [email protected]
t: (508)

679-8131

w: www.lightolier.com

LOT Series - 1.5-4.2 September 7, 2011

Specifications are subject to change without notice.
© Koninklijke Philips Electronics N.V., 2011. All rights reserved.

Job Information

Type:

Ordering Information

On Bus w/ Optional

Distribution

Optional Off/

Timed Off Bus w/

Distribution

DC

Fuse

Battery

Pack

Input

Circuit

Breaker

Inverter

Fuse

AC

Input

SS

System Rating (kW/kVA)

Input Volt. (V) : Input Curr. (A)

Output Volt. : Output Current*

OCB Pole Spaces Available
Without Trip Alarm
With Trip Alarm
Heat Rejection (btu/hr)
Weight (lbs)
Electronics
90 Min Battery
20 Min Battery
10 Min Battery

1.5

120 : 22.1

120/240 : N/A

277 : 9.8

120/208 : N/A

120 : 12.5

120/240 : N/A

277 : 5.4

120/208 : N/A

120/277 : 12.5/5.4

20
10

716

650
445

90
60

System Input/Output Ratings

SS

Bypass

Output

Hardwired

(Standard)

P
F

C

Series

LOT = Single
Phase UPS
System for
Emergency
Lighting
Applications

A = 120 V
G = 120/240 V
J = 277 V
L = 120/208 V

Input Voltage

Qty Circuit
Breakers
00X = Hardwire
01X = 1 OCB
02X = 2 OCB
03X = 3 OCB
04X = 4 OCB
.
.
20X
= 20 OCB

01A = 1 OCBA
02A = 2 OCBA
03A = 3 OCBA
.
.
10A
= 10 OCBA
(max. pole spaces 20)

LOT

Unit Size

1.5 = 1.5 kVA
2.2 = 2.2 kVA
3.0 = 3.0 kVA
3.5 = 3.5 kVA
4.2 = 4.2 kVA

Battery Time

S = 90 Min
X = 10 Min
Y = 20 Min

# Nol Circuit
Breakers
A = 1
B = 2
C = 3
D = 4
E = 5
F = 6
G = 7
H = 8
I = 9
J = 10
K = 11
L = 12
M = 13
N = 14
O = 15
P = 16
Q = 17
R = 18
S = 19
T = 20
Z = No Nol

Hardwired

System One-Line Diagram

A = 120 V
G = 120/240 V
J = 277 V
L = 120/208 V
Y = 120/277 V

Output Voltage

Nol

0 = None
1 = Yes
T = Nol w/
TDT

Breakers On
2nd Voltage
00 = 2nd
Voltage
Hardwire
or No 2nd
Voltage
01
02
03
.
.
19

Nol Voltage

1 = First
2 = Second
3 = Both
0 = No Nol

Qty Nol 2nd
Voltage
A = 1
B = 2
C = 3
D = 4
E = 5
F = 6
G = 7
H = 8
I = 9
J = 10
K = 11
L = 12
M = 13
N = 14
O = 15
P = 16
Q = 17
R = 18
S = 19
Z = No Nol

2.2

120 : 26.7

120/240 : N/A

277 : 11.9

120/208 : N/A

120 : 18.3

120/240 : N/A

277 : 7.9

120/208 : N/A

120/277 : 18.3/7.9

20
10

1050

650
445
195

90

3.0

120 : 39.4

120/240 : 19.1

277 : 17.1

120/208 : 22.1

120 : 25.0

120/240 : 25/12.5

277 : 10.8

120/208 : 25/14.4
120/277 : 25/10.8

20
10

1432

640

610
330
195

3.5

120 : 45.0

120/240 : 21.8

277 : 19.5

120/208 : 25.2

120 : 29.2

120/240 : 29.2/14.6

277 : 12.6

120/208 : 29.2/16.8
120/277 : 29.2/12.6

20
10

1670

640

610
330
195

4.2

120 : 47.0

120/240 : 23.5

277 : 20.3

120/208 : 27.0

120 : 35.0

120/240 : 35/17.5

277 : 15.2

120/208 : 35/20.2

120/277 : 35/15.2

20
10

2005

840
760
350
230

Rectifier

Inverter

Output

Circuit

Breaker

* Multi-voltage total loads not to exceed system rating.

Advertising