5

INSTALLATION

SQUARE WAVE TIG 175

5

REMOTE CONTROL CONNECTION

A remote control receptacle is provided on the case
front of the welder for connecting a remote control to
to the machine. A Foot Amptrol

tm

, foot activated remote

control, is included with the Square Wave TIG 175.
Refer to the Optional Accessories section of this man-
ual for other available remote controls.

CONNECTIONS FOR STICK (SMAW)
WELDING

STICK ELECTRODE CABLE AND WORK CABLE
CONNECTION

Refer to

Included Equipment in the Operation Section

of this manual for STICK welding equipment which is
included with the Square Wave TIG 175.

An electrode holder with cable is supplied with the
Square Wave TIG 175. Turn the Power Switch “OFF”.
Connect the cable quick connect plug into the
Electrode/Gas Output Receptacle and turn it clockwise
until it is tight. The work cable and work clamp are fac-
tory connected.