Troubleshooting, Caution – Lincoln Electric SQUARE WAVE TIG 175 IM605 User Manual

Page 21

Advertising
background image

14

TROUBLESHOOTING

14

SQUARE WAVE TIG 175

Observe all Safety Guidelines detailed throughout this manual

If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely, contact your Local
Lincoln Authorized Field Service Facility
for technical troubleshooting assistance before you proceed.

CAUTION

OUTPUT PROBLEMS

PROBLEMS

(SYMPTOMS)

POSSIBLE AREAS OF

MISADJUSTMENTS(S)

RECOMMENDED

COURSE OF ACTION

Machine regularly over heats - ther-
mostat opens, Yellow light on front
panel glows. The fan runs but
machine has no output.

1.

Welding application may
exceed recommended duty
cycle. Reduce the duty cycle.

2.

Dirt and dust may have
clogged the cooling channels
inside the machine. Blow out
unit with clean, dry
low pressure air.

3.

Air intake and exhaust louvers
may be blocked due to
inadequate clearance around
machine.

Contact your Local Lincoln Authorized
Field Service Facility
for technical
troubleshooting assistance.

Advertising