Parallel port service check, Power service check, Parallel port service – Lexmark 4090-001 User Manual

Page 22: Power service check’ on, Parallel port service check power service check

Advertising
background image

2-11

4090-001

Parallel Port Service Check

Power Service Check

FRU

Action

1

Parallel Port

Run a test page to be sure the printer can print.
Run the

’Parallel Port Test’ on page 3-5

. If the test

fails, replace the system board.

FRU

Action

1

Power Supply

Disconnect J3 from the system board and check
the following voltages on the power supply cable:

• J3-1 to GND = +5 V dc
• J3-3 to GND = +30 V dc
• J3-5 to GND = +13.5 V dc
• J3-6 to GND = +5 V dc
• J3-8 to GND = +5 V dc

If you do not have correct voltage, replace the
power supply. Be sure to unplug the printer before
you reconnect the power supply to the system
board.

3

Printhead Cable

Parallel Cable

Encoder Card

Turn off the printer. Disconnect one of the
printhead cables and turn on the printer. Look for a
symptom change. Check the failing part for shorts
and replace as necessary. Repeat this procedure
for the parallel cable and the encoder card.

4

System Board

If the symptom has not changed, replace the
system board.

Advertising