Loctite HYSOL P/N 98036 User Manual

Page 4

Advertising
background image

Page 3

3.

Technical Data

Dimensions (L x H x W):

approx. 11 13/16” x 9 15/32” x 2 17/32”
(Approx. 300 x 240 x 65 mm)

Total weight:

approx. 3 lbs. (1.4 Kg)

Connection cable with mains plug:

10 ft (3 m) long

Operating voltage:

110-120 VAC 50/60Hz

Power consumption

500W

Heating up time:

10 minutes

Operating temperature:

175-AIR approx. 383°F (195°C)
175-AIR-HT approx. 400°F (204°C)

Diameter of adhesive inlet:

1 11/16” (43 mm)

Extension cable:

max. 65ft (20 m) long

Wire cross section:

at least 16 a.w.g. (1.5 mm

2

)

Air Supply / Pneumatic

Minimum

45 p.s.i. (3 bar)

Maximum

100 p.s.i. (7 bar)

4.

Installation

Before using the tool for the first time check it carefully for signs of external damage. If
any transit damage is found DO NOT USE THE TOOL - return it to your supplier
immediately.

Steps 1 – 5 should be followed before connection to the mains supply:

1.

Insert the applicator stand into the grooves at the base of the handle. Stand
applicator on a flat surface.

2.

Connect the air supply hose to a clean, dry and regulated air supply using the
Quick-Disconnect fitting provided (use of a filter/regulator is recommended)

3.

Pull piston back fully and rotate upwards.

4.

Load two adhesive cartridges into the barrel of the tool and push fully forward.

5.

Rotate the piston down and slide forward fully until it contacts the rear of the
adhesive cartridge - it should engage about 5/16" (6-8mm) into the applicator
barrel.

6.

Connect tool to main power supply.

7.

Red ‘Power On’ indicator light illuminates.

8.

Allow the applicator to thoroughly warm up for 10 minutes. Do not attempt to
operate the applicator until this time has elapsed.

2

3

5

1

4

USERS AIR SUPPLY

Advertising