5.

Operation

Normal use:
• Fit the stand and place the applicator in an upright position on a flat surface.

• Plug the applicator into the power supply socket, and switch on the power

.

Wait 10

minutes for the applicator to reach its normal operating temperature.

• Squeeze the trigger to advance the piston and extrude molten adhesive through the

nozzle.

• To stop extruding adhesive simply release the trigger.

During use, the piston will advance into the barrel as the trigger is pulled. A point will
be reached where the piston no longer advances, and the sound of air escaping can
be heard - this indicates that the applicator needs reloading.
• Release the trigger.

• Pull the piston back.

• Insert a new adhesive cartridge.

• Operate the tool normally.

5.1. Adhesive Flow Rate Adjustment

The flow rate of adhesive is dependent on the air pressure to the piston, and this is
adjusted by varying the setting of the pressure regulator on the air supply to the
applicator.

The air pressure operating range for the applicator is:
Minimum

45 p.s.i. (3 bar)

Maximum

100 p.s.i. (7 bar)

.

USERS AIR SUPPLY

Advertising