Installation, Warning – Lincoln Electric POWER MIG IM736-D User Manual

Page 12

Advertising
background image

A-5

A-5

INSTALLATION

DO NOT ATTACH THE REGULATOR IF OIL,
GREASE OR DAMAGE IS PRESENT!

Inform your

gas supplier of this condition. Oil or grease in the
presence of high pressure oxygen is explosive.

3. Stand to one side away from the outlet and open

the cylinder valve for an instant. This blows away
any dust or dirt which may have accumulated in the
valve outlet.

Be sure to keep your face away from the valve
outlet when “cracking” the valve.

4. Attach the flow regulator to the cylinder valve and

tighten the union nut(s) securely with a wrench.

NOTE:

If connecting to 100% CO

2

cylinder, insert

regulator adapter between regulator and cylinder
valve. If adapter is equipped with a plastic washer,
be sure it is seated for connection to the CO

2

cylin-

der.

5. Attach one end of the inlet gas hose to the outlet

fitting of the flow regulator, the other end to the
POWER MIG 300 rear fitting, and tighten the union
nuts securely with a wrench.

6. Before opening the cylinder valve, turn the regula-

tor adjusting knob counterclockwise until the
adjusting spring pressure is released.

7. Standing to one side, open the cylinder valve slow-

ly a fraction of a turn. When the cylinder pressure
gauge pointer stops moving, open the valve fully.

Never stand directly in front of or behind the flow
regulator when opening the cylinder valve. Always
stand to one side.
------------------------------------------------------------------------

8. The flow regulator is adjustable. Adjust it to the flow

rate recommended for the procedure and process
being used before making the weld.

WARNING

WARNING

POWER MIG 300

Advertising