Troubleshooting, Caution – Lincoln Electric POWER MIG IM736-D User Manual

Page 38

Advertising
background image

E-10

TROUBLESHOOTING

E-10

POWER MIG 300

Observe all Safety Guidelines detailed throughout this manual

If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely, contact your

Local Lincoln Authorized Field Service Facility

for technical troubleshooting assistance before you proceed.

CAUTION

PUSH PULL WIRE FEEDING PROBLEMS

STALL FACTOR

- an adjustment on the

POWER MIG 300

that allows the welder to adjust the maximum amount of

power going to the rear drive motor. The purpose is to send only enough power to the rear drive motor to pull the
wire off the spool and get the wire up the torch liner.

STALL FACTOR NUMBER ADJUSTMENT

1. Turn the

POWER MIG 300

off.

2. Hold the Push-Pull Torch trigger in and turn the power back on. Continue to hold the trigger in while machine

powers up.

3. Once the machine displays "SF" in the left display and a number 5 to 35 in the right display the trigger can be

released.

4. Use the volts / trim knob to adjust the Stall Factor Number.

5. Once the Stall Factor Number is adjusted push the select switch up.

6. The display should scroll the word “SAVEd” if the number was changed. The display will scroll "no CHANGE" if

the SF number was not changed.

7. The machine should automatically switch back to normal operation after it is done saving the SF number.