Maintenance, G3503-[ ] installation or ser- vice tool usage, Removing and installing the g3503-[ ] cooler – Lincoln Electric INVERTEC POWER WAVE 450 IM524-D User Manual

Page 40

Advertising
background image

MAINTENANCE

D-5

D-5

POWER WAVE 450

RECOMMENDED TOOLS FOR INSTAL-
LATION OR SERVICE OF COOLER:

• absorbent towels
• alcohol wipe
• 3 mm allen wrench (G3503 only)
• socket wrench
• 4 inch long minimum socket extension
• 1/4, 5/16, and 3/8 hex standard depth sockets
• 5/32 allen socket
• medium blade slotted screwdriver
• large blade slotted screwdriver, 8 inches long

minimum

• two 7/16 open or box end wrenches
• one 7/8 open or box end wrench
• needlenose pliers
• two 10 inch long adjustable wrenches
• wire cutter
• molex pin removal tools
• tape measure
• small mechanic’s mirror
• flashlight
• dental pick
• digital multimeter (DMM)

G3503-[ ] INSTALLATION OR SER-

VICE TOOL USAGE

Fastener Usage

Qty.

Tool

Shroud to cooler base

4

all use 5/16 hex screw and 3/8 hex

Quick Disconnect (QD) bracket

2

nut. Relay may require large blade

Heat exchanger to cooler base

2

slotted screwdriver 8 in. long min.

Relay to cooler base

2

Screw to

4

3 mm allen wrench (G3503 only)

fasten reservoir to cooler base

5/16 Hex Socket (G3503-1 only)

Hose Clamp

10

1/4 hex or medium slotted screwdriver

Fan set screw

1

5/32 allen socket with wrench and 4
in. min. extension

Pump carbonator clamp screw

1

5/16 hex socket with ratchet wrench

Motor mounting bolts

4

two 7/16 open or box end wrenches

Motor access door

2

1/4 hex socket with wrench

Motor harness ground at motor

1

1/4 hex socket with wrench

terminals

2

needlenose pliers

relay terminals 1 and 2

2

large blade slotted screwdriver 8 in.
minimum long.

relay terminals 3 and 4

2

medium slotted screwdriver

All plumbing components

N/R

two 10 inch adjustable wrenches

REMOVING AND INSTALLING THE G3503-[ ]
COOLER

1. Preparation:

• Always switch off the Power Wave machine

power.

• Always disconnect the Power Wave machine

from service input power.

2. Remove cooler assembly G3503-[ ]:

a. remove gas cylinder(s) from tray.
b. remove cooler access panel.
c. Remove both fasteners from base that hold cool-

er in place. Remove ground lead, if present.
Carefully pull cooler assembly rearward, until
cooler’s Molex connectors are visible.

d. disconnect cooler’s connectors from the P3 and

P4 harnesses. Continue pulling the cooler out of
the Power Wave.

3. If necessary, perform periodic maintenance or ser-

vice on the cooler.

4. Reinstall cooler by reversing tasks in step 2. Be sure

to reattach ground lead, if previously removed.

5. If necessary, fill cooler with selected coolant to spec-

ified level (see Fig. 1).

6. Attach desired water-cooled accessory (gun and

wire feeder or TIG torch) to cooler’s QDs.

7. Reconnect service input power to the Power Wave:

• verify that the reconnect panel setting and lead

placement match the service voltage.

8. Prime the cooler:

a. Install the Set-up overlay.
b. Keep accessories’ hose lengths horizontal,

either coiled or straight, and no higher than 4
feet of the specified coolant level (Fig. 1).

c. Switch on the Power Wave machine.
d. Press the "WATER COOLER ENABLE" button

so that the "WATER COOLER ENABLED" light
is illuminated .

e. Press the "PRIME WATER COOLER" button

until the "WATER COOLER PRESSURE" light is
steadily illuminated.

9. Check coolant level. Add more if required.

Advertising