Maintenance, G3503-[ ] cooler periodic maintenance, G3503-[ ] cooler service – Lincoln Electric INVERTEC POWER WAVE 450 IM524-D User Manual

Page 41

Advertising
background image

MAINTENANCE

D-6

D-6

G3503-[ ] COOLER PERIODIC MAINTENANCE

1. Preparation:

• Always switch off the Power Wave machine power.
• Always disconnect the Power Wave machine from

service input power.

• Do not remove the pump relief valve’s 3/4 in. acorn

hex nut or attempt to adjust the relief valve setting.

2. Remove the G3503-[ ] cooler from the Power Wave

machine.

3. Clean the pump’s inlet strainer:

• Drain the reservoir of coolant and dispose of it in an

environmentally responsible manner (see
Recommended Coolants).

• Place absorbent towels underneath pump head.
• Hold pump head to apply countertorque when loos-

ening strainer’s 7/8 acorn nut. Do not confuse with
3/4 acorn nut. Remove nut and slide inlet strainer
down and out from pump head.

• Gently rinse strainer under running water to thor-

oughly clean it.

• Use the mirror to inspect inside of pump for contam-

ination. Carefully remove hardened debris with den-
tal pick if necessary, without scratching inside of the
pump.

• Reinstall strainer and acorn nut, tightening with

75±15 in.-lbs. of torque. Wipe dry all areas wetted by
coolant. Dispose of towels in an environmentally
responsible manner (see Recommended Coolants).

4. Gently rinse the reservoir’s strainer under running water to

thoroughly clean it.

5. Remove fan shroud and inspect hoses and electrical har-

nesses for kinking or damage (cut, abrasion, swelling,
etc.). Replace if necessary.

6. Remove accumulated dust from cooler, especially from the

motor and heat exchanger, by blowing it off with shop air
or vacuuming it out.

• The heat exchanger fins are sharp but can be easily

bent. Treat them with care to avoid personal injury
and damaging them.

• Remove the cooler from the machine for a more thor-

ough cleaning job.

7. Motor lubrication is recommended once a year:

• Remove plug over lube port at top of motor near fan

end.

• Add 20 drops of electric motor or SAE 10 oil then

reinstall plug.

8. Flush coolant from the system and replace with fresh, rec-

ommended coolant at least once a year. More frequent
flushing may be necessary, depending upon a user’s par-
ticular system or its usage.

NOTE: Never run the pump dry. Always use a recommended

coolant, otherwise pump damage may result.

9. Reinstall the G3503-[ ] cooler into the Power Wave

machine.

G3503-[ ] COOLER SERVICE

1. Preparation:

• Always switch off the Power Wave machine power.
• Always disconnect the Power Wave machine from

service input power.

• Do not remove the pump relief valve’s 3/4 in. acorn

hex nut or attempt to adjust the relief valve setting.

2. Remove the G3503-[ ] cooler from the Power Wave

machine whenever:

• replacing major cooler components (i.e. pump,

motor, heat exchanger, etc.).

• replacing hoses and electrical harnesses that are

kinked or damaged (cut, abraded, deteriorated or
swollen, etc.).

• investigating suspect coolant leakage.

3. Pump replacement:

a. Drain the reservoir of coolant and dispose of it in an

environmentally responsible manner (see
Recommended Coolants).

b. Remove fan shroud.
c. Place absorbent towels underneath pump head and

wherever coolant system is opened.

d. Carefully pull pump inlet hose and its elbow from

reservoir (bottom).

e. Loosen pump outlet hose clamp at QD then carefully

remove from fitting.

f. Disconnect v-band clamp from motor and remove

pump:

• Do not drop or lose drive coupling between pump

and motor.

• Do not discard old pump. Remove both fittings,

Keep v-clamp, Seal old pump in a waterproof bag,
Package into protective container, and Return to
nearest Lincoln Electric FSS center.

g. Install new pump and v-band clamp:

• Do not apply any lubricant to pump’s drive coupling.
• Pump body is properly oriented with its strainer at

the 6:00 position.

• Tighten v-clamp with 15 to 30 in-lbs. of torque.

h. Attach coolant lines to QD and reservoir.
i. Wipe dry all areas wetted by coolant. Dispose of tow-

els in an environmentally responsible manner (see
Recommended Coolants).

j. Reinstall cooler into machine.

4. Motor removal or replacement:

• Do not reuse the 4 internal-tooth star washers.

Replace with new parts..

5. Installing the fan:

• Slide onto motor shaft until the fan is located

between 0.25 to 0.50 inches from the heat
exchanger.

• Tighten set screw with 65 to 75 in-lbs of torque

against motor shaft’s flat.

• Fan rotation is counterclockwise, as viewed from

fan-end of motor’s shaft.

• Fan pulls air through the heat exchanger, blows it

over the motor, then exhausts it through the reser-
voir.

Advertising