Diagram B: Side View-Alcove & Parallel Installation

Diagram A: Top View-Parallel Installation

K

B

A

E

C

D

*L

K

Floor Protection

Floor Protection

Floor Protection

G G

F

F

72" Min.

H

I

M

J

I

J

H

E

E

L

48”

Maximum

Depth

Diagram C: Top

View-Corner

Installation

N

P

T

PIPE

INSTALLATION

A

B (1)

C

D (1)

E†

F (1,4)

G (4)

6” Single Wall

Residential or
Alcove

USA-16”

CAN-483mm

14”

356mm

USA-21”

CAN-610mm

12-1/2”
318mm

8”

200mm

9-3/4”

248mm

USA-18”

CAN-533mm

v

6” Single w/

Pipe Shield

Residential or
Alcove

USA-10”

CAN-330mm

8”

200mm

USA-18”

CAN-533mm

9-1/2”

241mm

8”

200mm

5-1/2”

140mm

USA-13-1/2”
CAN-419mm

6” Double Wall

Residential or
Alcove or Mobile
Home*

USA-10”

CAN-330mm

8”

200mm

USA-18”

CAN-533mm

9-1/2”

241mm

8”

200mm

5-1/2”

140mm

USA-13-1/2”
CAN-419mm

PIPE

INSTALLATION

H (2)

I (6)

J (2)

K

L (5)

M

Single Wall

Residential or
Alcove

USA-33-3/4”

CAN-1111mm

USA-47-3/4”

CAN-1340mm

USA-33-1/2”

CAN-1003mm

USA-16”

CAN-450mm

USA 0"

CAN-200mm

84”

2134mm

v

Single w/

Pipe Shield

Residential or
Alcove

USA-33-3/4”

CAN-1111mm

USA-41-3/4”

CAN-1188mm

USA-33-1/2”

CAN-1003mm

USA-16”

CAN-450mm

USA 0"

CAN-200mm

84”

2134mm

Double Wall
Air-Cooled

Residential or
Alcove or Mobile
Home*

USA-33-3/4”

CAN-1111mm

USA-41-3/4”

CAN-1188mm

USA-33-1/2”

CAN-1003mm

USA-16”

CAN-450mm

USA 0"

CAN-200mm

72”

1829mm

† USA=8" (200mm) from door opening,
Canada=8" (200mm) from sides and back
of unit

u

Dimensions to Stove Body

v

Clearances may only be reduced by means

approved by the regulatory authority.

* Mobile Home - USA only

PIPE

INSTALLATION

Nu

Pu

T (6)

Single Wall

Residential or
Alcove

30"

762mm

36"

914mm

USA-58-1/2”

CAN-1645mm

v

Single w/

Pipe Shield

Residential or
Alcove

30"

762mm

36"

914mm

USA-52”

CAN-1486mm

Double Wall
Air-Cooled

Residential or
Alcove or Mobile
Home*

30"

762mm

36"

914mm

USA-52”

CAN-1486mm

Footnotes:

1- These dimensions to the stove body are for reference only. Actual

distances should be measured from the stove’s flue collar.

2- Minimum noncombustible hearth pad dimensions.

3- Shield shall be attached to the rear of the stove pipe with a 1” air

space and must run from the top of the stove to the ceiling.

4- Not applicable to alcove installations.

5- In corner applications, when installed at minimum back wall clear-

ances, the required floor protection is dimensioned off the back

plane of the stove, therefore the floor protection required off the

back corners (at a 45 degree angle) only needs to extend to the

wall. This situation will only occur in CANADA installations.

6- Reference dimension only, to assist in planning the installation.

Clearances to connector pipe shall be measured from the flue

collar of the stove.

Top View -

Corner Clearance,
Stove and Flue to Wall

6” Ø

Flue Collar

INSTALLATION CLEARANCES - REFER TO FIGURES 2, 3 ANd 4

NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.

Figure 2

Figure 3

Figure 4