Field wiring, Figure 1 – Lennox Hearth ELITE E36ODGPE User Manual

Page 10

Advertising
background image

0

NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE.

FIELd WIrING

Caution: Label all wires prior to disconnection

when servicing controls. Wiring errors can

cause improper and dangerous operation.

Verify proper operation after servicing.

Refer to Figure 10 for the wiring schematic

for these fireplaces.

This fireplace is completely wired internally.

On the right hand side of the fireplace, at the

rear, are four (4) wires required to connect the

Battery and switch for operation.

Two brown wires are for the connection of the

switch. These are labeled SW and SW. A black

and red pair are for connection to the battery

pack. These are labeled (+) and (–).

These wires are for low voltage current. An

electrical box has been provided to contain both

the switch and battery pack. Mount the box in

an appropriate location within the length of the

wiring provided. Feed all four wires through

one of the lower inlets to the box. Connect the

switch wires to the switch and the corresponding

(+), (–) to the battery holder.

Install two D-cell batteries (not provided) and

test the switch before closing the switch box

(refer to Figure 11 ). The igniter should spark

to the pilot when the switch is on.

Figure 1

0

Figure 1

1

Switch

Cover

Weather Seal

Orient Batteries Vertically

to Fit Within Box

INtErMIttENt ELECtrONIC WIrING dIAGrAM

BrOWN

BrOWN

BLACK

BAttEry

WALL SWItCH BOx

BLACK (SENSOr)

BLACK (IGNItOr)

SPArK tO PILOt IGNItOr

IGNItOr MOduLE

3V

rEd

PILO

T

IN

OU

T

VEN

T

LO

HI

TH

TP

TH

TP

IN

OrANGE (tHtP)

BLACK (tP)

GrEEN (tH)

LIMIt

SWItCH

uMBILICAL COrd (9 Feet)