Lennox Hearth ELITE E36ODGPE User Manual

Page 13

Advertising
background image

NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE.

3

Figure 17

CHECKING APPLIANCE OPErAtION

With gas line installed run initial system check-

out before installing any additional accesso-

ries. Follow the lighting instructions provided

in the Care and Operation Instructions.

Note: Lighting Instructions are also found on

the literature tag tied to the gas piping next

to the gas valve. To access the tag, open the

lower control compartment door (refer to

Figure 13 - Valve Access ).

When first lighting the appliance, it will take

a few minutes for the line to purge itself of

air. Once purging is complete, the pilot and

burner will light and operate as indicated in

the instruction manual. Subsequent lighting

of the appliance will not require such purging.

Inspect the pilot flame (remove logs, if neces-

sary, handling carefully).

After the logs have been placed and the

fireplace has been checked for proper flame

presentation, use the remaining rock to fill in

voids and spaces. Remember, you may need

to access the high/low flame control beneath

the refractory cover.

Electronic Appliance Checkout

To light the burner, turn ‘ON’ the remote wall

switch. The battery will energize a spark that

will light the pilot. The pilot flame will engulf

the sensor and open the main valve. Within

seconds the main burner will light. Ensure the

ignitor lights the pilot. The pilot flame should

engulf the sensor as shown in Figure 17.

Figure 18

Clearances To Combustibles

ELECtrONIC

Pilot

Hood

Sensor

Ignitor

6" Minimum

For Combustible

Materials

2" Max.

3-3/4" Max.

See Note

29" Min.

Wall

Switch

5"

Min.

Note: the Area Above the Face to the top Of the Spacers

Must Be Non-Combustable Materials

FIrEBOx FINISHES

There are a wide variety of "finished looks" for your outdoor fireplace, from formal wall decor with

elaborate mantels to rustic wood paneling or warm brick facings.

Only noncombustible materials like marble, stone, tile, brick, etc. may overlap the top and sides of

the front facing. Seal all joints between the black facing and wall surrounds to prevent air intrusion.

Use noncombustible caulking materials only to seal the metal facing to the surround material on

the finished wall. See Figure 18.

CAutION: dO NOt BLOCK tHE FACE OPENING ON tHESE FIrEBOxES. dOING SO MAy CrEAtE

A POtENtIAL FIrE HAzArd.

Carbon Monoxide Poisoning: Early signs of carbon monoxide poisoning are similar to the flu

with headaches, dizziness and/or nausea. If you have these signs, obtain fresh air immediately.

turn off the gas supply to the appliance and have it serviced by a qualified professional, as

it may not be operating correctly.

Advertising