Internal and external scsi device termination – LSI SYM8953U User Manual

Page 37

Advertising
background image

3.75 pc

10.25 pc

11.25 pc

38.25 pc

4.333 pc

48.583 pc

52.5 pc

34.5 pc

44.25 pc

Detailed Installation Procedure

2-21

2.2.6.3 Internal and External Bus Connections

If you have both internal and external SCSI device connections to your
host adapter, you must terminate the last internal and last external
devices on the SCSI bus. You must also disable the termination on all
other devices. Termination on the host adapter is automatically disabled
in this case.

Figure 2.14

shows an example of how termination is determined for this

SCSI bus configuration.

Figure 2.14 Internal and External SCSI Device Termination

Last device on Bus -

Does not end Bus -

Host Adapter Termination

Do not end Bus -

Last Device on Bus -

Terminators Enabled

Terminators Disabled

Automatically Disabled

Terminators Disabled

Terminators Enabled

Advertising