Troubleshooting, Caution – Lincoln Electric IDEALARC R3R-300 User Manual

Page 15

Advertising
background image

D-3

TROUBLESHOOTING

D-3

IDEALARC® R3R, -300, -400, -500

Observe all Safety Guidelines detailed througout this manual

If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely, contact your Local
Lincoln Authorized Field Service Facility
for technical troubleshooting assistance before you proceed.

CAUTION

FUNCTION PROBLEMS

PROBLEMS

(SYMPTOMS)

POSSIBLE

CAUSE

RECOMMENDED

COURSE OF ACTION

Machine input contactor closes but
has no or low output. Open circuit
voltage should be 67 to 71 volts.

Machine has maximum output but
no control.

1. Electrode or work lead loose or

broken.

2. Open transformer primary or

secondary circuit.

3. Supply line fuse blown.

4. Input line grounded causing

single phase input.

5. Input leads not connected to

contactor.

6. Latching resistor, R3, open.

7. Control circuit problems.

1. Possible defective power SCR.

2. Possible defective control board.

If all recommended possible areas
of

misadjustment

have

been

checked and the problem persists,
Contact

your

local

Lincoln

Authorized Field Service Facility.

Advertising