D-6

TROUBLESHOOTING

D-6

IDEALARC® R3R, -300, -400, -500

Observe all Safety Guidelines detailed througout this manual

If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely, contact your Local
Lincoln Authorized Field Service Facility
for technical troubleshooting assistance before you proceed.

CAUTION

FUNCTION PROBLEMS

PROBLEMS

(SYMPTOMS)

POSSIBLE

CAUSE

RECOMMENDED

COURSE OF ACTION

Current control on machine not
functioning.

Optional remote current control not
functioning. See Troubleshooting
Procedures before connecting.

1. Current control switch in wrong

position.

2. Current control switch defective.

3. Current control potentiometer

defective.

4. Lead or connection in control

circuit open.

5. Defective control or circuit

boards.

1. Current control switch in the

wrong position.

2. Leads 75, 76 and 77 not con-

nected to correct numbers on
models with terminal strip.

3. Remove control leads broken.

4. Remote control potentiometer

open.

5. Lead or connection in current

control circuit open.

6. Control PC board plug discon-

nected or loose.

7. Control circuit problems.

If all recommended possible areas
of

misadjustment

have

been

checked and the problem persists,
Contact

your

local

Lincoln

Authorized Field Service Facility.