Troubleshooting, Caution – Lincoln Electric 500 User Manual

Page 36

Advertising
background image

E-3

TROUBLESHOOTING

E-3

VANTAGE 500 CUMMINS

Observe all Safety Guidelines detailed throughout this manual

If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely, contact your
Local Lincoln Authorized Field Service Facility for technical troubleshooting assistance before you proceed.

CAUTION

PROBLEMS

(SYMPTOMS)

POSSIBLE

CAUSE

RECOMMENDED

COURSE OF ACTION

Battery does not stay charged.

Engine will not idle down to low
speed.

Engine will not go to high idle when
attempting to weld.

Engine will not go to high idle when
using auxiliary power.

1. Faulty battery .
2. Faulty engine alternator.
3. Loose or broken lead in charging

circuit.

4. Loose fan belt may need tighten-

ing.

1. Idler switch in HIGH idle position,

make sure switch is set to AUTO.

2. External load on welder or auxil-

iary power.

3.

Faulty, Weld Control PCB
(Printed Circuit Board) or elec-
tronic governor controller.

1. Poor work lead connection to

work.

2. Welding Terminals switch in

wrong position.

3. No open circuit voltage at output

studs.

4. Faulty electronic governor con-

troller or Weld Control PCB.

1. Broken wire in auxiliary current

sensor wiring.

2. Auxiliary power load is less than

100 watts.

3. Faulty electronic governor con-

troller or Weld Control PCB.

If all recommended possible areas of
misadjustment have been checked
and the problem persists, Contact
your local Lincoln Authorized
Field Service Facility.

FUNCTION PROBLEMS