Troubleshooting, Caution – Lincoln Electric SAM400 User Manual

Page 27

Advertising
background image

E-4

TROUBLESHOOTING

E-4

SAM400 & 650

Observe all Safety Guidelines detailed throughout this manual

If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely, contact your Local
Lincoln Authorized Field Service Facility
for technical troubleshooting assistance before you proceed.

CAUTION

FUNCTION PROBLEMS

PROBLEMS

(SYMPTOMS)

POSSIBLE CAUSE

RECOMMENDED

COURSE OF ACTION

Output without control - one mode only

(Constant or Variable Voltage)

Output without control - both modes

(Constant and Variable Voltage)

SCR Bridge Test (See Procedure)

Continuity test. (Note B Pg. E-2).

10. Voltage higher than 22 volts DC.

a) If between 22 and 100 volts, replace both

Control Boards. (Note A Pg. E-2).

b) If voltage is greater than 100 volts:

1)Check diode D-4 for a short. See Procedure
2)Replace both Control Boards but only if

voltage between Pin #75 and #227 is
less than 100 volts DC.

11. Voltage less than 15 volts DC, replace

Control Board #1. (Note A Pg. E-2).

12. Voltage within limits.

a) Check SCR Bridge. See Procedure
b) Check generator field coil resistance.

1)Disconnect blue and brown field coil

leads. Resistance should be about 10
ohms.

c) Replace Control Board #1. (Note A Pg. E-2).
d) Check Control Board #2 by following Step

2, Pg E-2.

If bridge tests good proceed to next step.

1. Turn machine off.
2. Remove both Control Boards.
3. Place electrode polarity switch in con-

stant voltage positive position.

4. Toggle switch to mode in question.
5. Check continuity of the following (Note

B Pg. E-2):

a) Constant Voltage

1)Work to Pin #217 of the connector for

Control Board #2.

2)Pin #203 of the connector for Control

Board #2 to Pin #216 of the connector
for Control Board #1.

3)Between corresponding numbers of the

connectors for both Control Boards,
Pin #75, 216 and 227.

b) Variable Voltage

1)Blue field lead to Pin #201 of the con-

nector for Control Board #2.

2)Pin #202 of the connector for Control

Board #2 to Pin #216 of the connector
for Control Board #1.

3)Between corresponding pins of the

connectors of both Control Boards, Pin
#75, 216 and 227.