Lenovo 6532 User Manual

Page 45

Advertising
background image

• Follow the suggested actions in the order in which they are listed in the Action column until the problem is

solved.

• See Chapter 7 “Parts listing, RS210 Types 6531, 6532, 6533, and 6534” on page 175 to determine which

components are customer replaceable units (CRU) and which components are field replaceable units (FRU).

• If an action step is preceded by “(Trained service technician only),” that step must be performed only by

a trained service technician.

Memory Logging Limit Reached
for DIMM nStatus on Memory
Subsystem DIMMnStatus.(n = DIMM
number)

Error

The memory logging limit
has been reached.

1. Update the server firmware to

the latest level.

Important: Some cluster
solutions require specific code
levels or coordinated code
updates. If the device is part
of a cluster solution, verify
that the latest level of code
is supported for the cluster
solution before you update the
code.

2. Reseat the DIMMs and run the

DSA memory test.

3. Replace any DIMM that is

indicated by a lit error LED.

Memory DIMM Configuration Error
for DIMM nStatus on Memory
Subsystem DIMM nStatus.(n = DIMM
number)

Error

A DIMM configuration error
has occurred.

Make sure that DIMMs are
installed in the correct sequence
and have the same size, type,
speed, and technology.

Sensor DIMM n Temp has transitioned
to critical from a less severe state.(n
= DIMM number)

Error

A sensor has changed to
Critical state from a less
severe state.

1. Make sure that the fans are

operating, that there are no
obstructions to the airflow, that
the air baffles are in place and
correctly installed, and that
the server cover is installed
and completely closed.

2. If a fan has failed, complete

the action for a fan failure.

3. Replace DIMM n.

(n = DIMM number)

Chapter 4

.

Diagnostics

37

Advertising
This manual is related to the following products: