Installing the system board

Note: When you reassemble the components in the server, be sure to route all cables carefully so that they
are not exposed to excessive pressure.

Notes:

1. When you reassemble the components in the server, be sure to route all cables carefully so that they

are not exposed to excessive pressure.

2. When you replace the system board, you must either update the server with the latest firmware or restore

the pre-existing firmware that the customer provides on a diskette or CD image. Make sure that you
have the latest firmware or a copy of the pre-existing firmware before you proceed. See “Updating the
firmware” on page 211
“Updating the Universal Unique Identifier (UUID)” on page 168 “Updating the
DMI/SMBIOS data” on page 170
for more information.

Important: Some cluster solutions require specific code levels or coordinated code updates. If the device is
part of a cluster solution, verify that the latest level of code is supported for the cluster solution before you
update the code

To install the system board, complete the following steps:

1. Read the safety information in “Important Safety Information” on page 1 and “Guidelines for trained

service technicians” on page 115.

2. Align the system board with the chassis, and replace the screws that secure the system board.

3. Reinstall the microprocessor and heat sink (see “Installing the microprocessor” on page 141).

4. Reinstall the DIMMs (see “Installing a memory module” on page 125).

5. Reinstall the DIMM air baffle (see “Removing and installing the DIMM air baffle” on page 121).

6. If necessary, reinstall ServeRAID-BR10il SAS/SATA controller (see “Installing an IBM ServeRAID-BR10il

SAS/SATA controller” on page 159).

7. Reinstall the PCI riser-card assemblies and PCI cards, if any were installed (see “Installing the riser-card

assembly” on page 157 and “Installing a PCI card” on page 132).

8. Reinstall the virtual media key (see “Replacing the virtual media key” on page 165).

9. Reinstall the hypervisor flash device (see “Installing a USB embedded hypervisor flash device” on page

134).

10. Reconnect all cables to the system board that were disconnected.

11. Install the cover (see “Removing and installing the cover” on page 119).

12. Slide the server into the rack.

13. Reconnect the power cords and any cables that you removed.

14. Turn on the peripheral devices and the server.

Important: Perform the following updates:

• Either update the server with the latest RAID firmware or restore the pre-existing firmware from a diskette

or CD image.

• Update the UUID (see “Updating the Universal Unique Identifier (UUID)” on page 168.

• Update the DMI/SMBIOS (see “Updating the DMI/SMBIOS data” on page 170).

Replacing the power supply

This procedure is used when replacing a defective power supply.

When you remove or install the power supply, observe the following precautions.

Chapter 6

.

Replacing FRUs

145

Advertising