Leviton Plug-In Serial Interface Module RZCP User Manual

Page 2

Advertising
background image

lIMItED 5 YEaR WaRRaNtY aND EXCluSIoNS

Leviton warrants to the original consumer purchaser and not for the benefit of anyone else that this product at the time of its sale by Leviton is free of defects in materials and workmanship under normal and proper use for five years from the
purchase date. Leviton’s only obligation is to correct such defects by repair or replacement, at its option, if within such five year period the product is returned prepaid, with proof of purchase date, and a description of the problem to leviton
Manufacturing Co., Inc., att: Quality assurance Department, 59-25 little Neck Parkway, little Neck, New York 11362-2591.
This warranty excludes and there is disclaimed liability for labor for removal of this product or reinstallation.
This warranty is void if this product is installed improperly or in an improper environment, overloaded, misused, opened, abused, or altered in any manner, or is not used under normal operating conditions or not in accordance with any
labels or instructions. there are no other or implied warranties of any kind, including merchantability and fitness for a particular purpose, but if any implied warranty is required by the applicable jurisdiction, the duration of any such
implied warranty, including merchantability and fitness for a particular purpose, is limited to five years. leviton is not liable for incidental, indirect, special, or consequential damages, including without limitation, damage to, or
loss of use of, any equipment, lost sales or profits or delay or failure to perform this warranty obligation
. The remedies provided herein are the exclusive remedies under this warranty, whether based on contract, tort or otherwise.

oPERatIoN

NotE: For complete details on operating the

Primary Programmer/Remote, refer to the

instruction guide for that particular device.
The RZCØP is intended for use by developers

who want to develop products that can transmit

signals to and receive signals from ViziaRF

TM

products on a Z-Wave

TM

network. A relatively

high level of programming knowledge is required

to develop products that use these interfaces.

The interface uses a simple ACSII protocol to

communicate to the controlling equipment. If you

are an end user who has purchased this product

to work with another product that was designed

for this purpose, please refer to that product’s

owner’s manual for operating instructions.
If you are a developer who has purchased this

interface to develop a ViziaRF

TM

compatible

product, you will need the RZCØP Tech Note,

which contains the information needed to allow

proper interface communication. Please visit our

website listed below to download the RZCØP

Tech note.

Plug-In Serial Interface Module is

functioning improperly

- Confirm that the device is being supplied

from a 120V, 60Hz AC source ONLY.

- Confirm that the unit is programmed

properly. Repeat “INSTALLING YOUR

INTERFACE MODULE” section to verify

that it has been included into the Z-Wave

TM

network.

• Programmer/Remote does not operate

lights

- Check association.
- Ensure that Plug-In Serial Interface Module

was properly updated.

tRouBlESHootING

DI-000-RZC0P-00C

For additional information, contact leviton’s

techline at 1-800-824-3005 or visit leviton’s

website at www.ViziaRF.com

Protected under U.S. Patent Number 6,388,399

and patents pending and licensed under U.S.

Patents Numbers 5,905,442, and 5,982,103

NotE: It is very important to accurately

Exclude devices from the network when

moving or removing a device from a Z-Wave

TM

network. This ensures that all information has

been removed from your Primary Programmer/

Remote’s information table and is not counted

on to be a part of the mesh network.
a) If using a Leviton Z-Wave

TM

Programmer/

Remote, Cat. No. RZCPG, press the Menu

button and scroll down to System Setup.

Press the center button to select System

Setup Menu. Press the center button to

select Network. Scroll down to <Exclude

Node> and press the center button.

B) If using RZCPG Programmer/Remote

you will be prompted to prepare device

for exclusion. To do this, you must put

the Plug-In Serial Interface Module into

programming mode.

C) To access Program mode, press and hold

programming button until the LED turns

Amber. You are now in Programming mode.

NotE: If the LED on the Plug-In Serial

Interface Module turns solid Red while

excluding, there has been a communication

error.

D) While standing close to the Plug-In Serial

Interface Module (approximately 2-5 ft.),

press the center button to <Exclude> device

from the network.

Excluding Plug-In Serial

Interface Module from

Network:

Step 4

This equipment has been tested and found

to comply with the limits for a Class B Digital

Device, pursuant to Part 15 of the FCC

Rules. These limits are designed to provide

reasonable protection against harmful

interference in a residential installation.

This equipment generates, uses, and can

radiate radio frequency energy and, if not

installed and used in accordance with the

instructions, may cause harmful interference

to radio communications. However, there is

no guarantee that interference will not occur

in a particular installation. If this equipment

does cause harmful interference to radio or

television reception, which can be determined

by turning the equipment OFF and ON,

the user is encouraged to try to correct the

interference by one or more of the following

measures:
• Reorient or relocate the receiving Antenna.
• Increase the separation between the

equipment and the receiver.

• Connect the equipment into an outlet on

a circuit different from that to which the

receiver is connected.

• Consult the dealer or an experienced radio/

tv technician for help.

FCC CoMPlIaNCE StatEMENt

Factory Default:

If your module is not responding, or you are

unable to control it after you have tried to Include/

Exclude it multiple times, it may be necessary to

reset the module to its original factory settings. To

accomplish this, proceed as follows:
• Press and hold the programming button until

the LED flashes Amber and then turns solid

Red. Release the button and wait until the

LED blinks Green. NotE: This can take up

to a minute. The module is now reset. Once

the module is reset, it will be necessary to Re-

Include it to a network before it can be used.

CautIoN:

SETTING A DEVICE TO A

FACTORY DEFAULT DOES NOT EXCLUDE

THAT DEVICE FROM A NETWORK. THE

EXCLUSION PROCEDURE MUST STILL BE

FOLLOWED TO REMOVE THE DEVICE FROM

THE PRIMARY REMOTE’S INFORMATION

TABLE. FAILURE TO DO SO MAY RESULT IN

SYSTEM THAT IS SLOW TO RESPOND, OR

MAY FAIL TO RESPOND TO SOME DEVICES.

Wall Receptacle

RS232 Cable

Plug-In Serial
Interface Module

NOTE: Programmer/Remote must be in
close proximity to Plug-In Serial Interface
Module when including into network

RZCPG Programmer/
Remote

Including Plug-In

Serial Interface

Module into

Z-Wave

tM

Network:

Step 3 cont’d

Step 4 cont’d

www.ViziaRF.com

CoMMuNICatIoN SEttINGS

NotE: The following general information applies

to the RS232 Interface.
To configure your device to communicate with the

interface, use the following data conventions:
9600 BauD
8 Data
1 StoP
No PaRItY
If you wish to send these commands from a

PC, run the Microsoft Windows

®

Hyper Terminal

program or an equivalent program. Then select

Local Echo, Line Feed and Carriage Return

inbound and outbound. This allows you to see the

characters that you are typing as well as keep the

responses from overwriting typed characters.

Advertising