La gard locks bv, Manual programming lg 39e multi user – LG 39E Multi User Manual

Page 3

Advertising
background image

Kantooradres:

Postadres:

Vlijtstraat 40

Postbus 127

NL-7005 BN Doetinchem

NL-7000 AC

H.R. te Arnhem nr: 09087869

Tel: (+31) 314 376 876

E-mail: [email protected]

Internet: http://www.lagard.nl

BTW nr: NL 8038.72.987.B01

Fax: (+31) 314 376 878

LG 39E Combogard EN

Revise: 1

Datum: 16-02-05

3

LA GARD Locks BV

Manual programming

LG 39E Multi User

Factory Mode

(Pre-Setup-mode)

The lock maybe mounted in the factory mode. It opens when

pressing key “1” and it sends a silent alarm signal.

The advantage is that there is only 1 version storage and an

easy use during mounting.

Exit the Factory-Mode

Keep pressed the key “0” until the double signal (4-5

seconds). Now the manager code is 555555.

Code length and program selection

(6-9 digit code length is possible)

The code length and program selection are made with the

function “8” in a group of 2 digits. The first digit is the code

length and the second one is the program number.

Program 0 = Manager mode (operation with parallel code)

Program 1 = Manager mode with delay override

Program 2 = Operation with two codes

Program 3 = Two code operation with delay override

Program 4 = Manager mode with alarm

Program 5 = Manager with alarm and with delay override

Program 6 = Two code operation with alarm

Program 7 = Two code operation, alarm and delay override

Programming

(function 8)

Enter the manager code “555555” and keep pressed the

last number until the double signal is repeated (LED is on)

and enter “8”. Enter the group of 2-digits (code length and

program number) double signal and repeat the group for

confirmation (double signal).

In case of the 7-digit codes the manager code is 7x “5”.

Install (Enable) user

(function 1)

Enter manager-code and keep last digit pushed until LED

stays on. Press „1“ (double signal) and enter user-ID Nr. f.i.

„1“ (double signal). Enter user code (double signal) and to

confirm, enter the code again. Double signal and LED

extinguished.

In case a

new code

is not

accepted (3-time-signal),

this code

is too similar to an already existing code. Select new code.

NOTE: Users who are not installed in this stage will be

blocked after changing the manager code!

Program “freeze”

After changing the manager code the program is „frozen“ and

the program settings can only be changed after a reset to

Factory Mode.

Reset to Factory Mode

In case the manger code is lost or the setting of the lock has

to be changed, a reset can be executed by means of the

RESET-BOX (PN#6066). Unplug battery from the lock or

entry.

Push the "0" button for ca. 3 minutes (or leave it for

10minuts powerless) and plug the RESET-BOX in the BAT-

connection of the lock. Wait until a longer signal. (0,5 sec)

The Reset-Box requires a connected 9V-DURACELL

ALKALINE-battery.

The lock is in FACTORY MODE.

Disconnect Reset-Box and

plug battery back again. Lock opens with “1”.

Safety notice: Do not assign code to the users of no use for the time being.

Remove the codes. (Function 3 and user number)