Installation, Ln-10,dh-10 control switch setup, Setup dip switch access – Lincoln Electric FLEXTEC 450 CE User Manual

Page 15: Setting the dip switches

Advertising
background image

A-8

INSTALLATION

FLEXTEC™ 450 CE

A-8

LN-10,DH-10 CONTROL SWITCH
SETUP

Initial set up of the LN-10, DH-10 control for the sys-
tem components being used and for general operator
preferences is done using a pair of 8-pole DIP switch-
es located inside the LN-10, DH-10 control box.

Setup DIP Switch Access

1) Shut off the input power to the LN-10, DH-10 con-

trol by turning off the power at the welding power
source it is connected to.

2) Remove the two screws on the top of the LN-10,

DH-10 control box door and swing the door down
to open.

3) Locate the two 8-pole DIP switches, near the top

left corner of the LN-10, DH-10 Control P.C. board,
labeled S1 and S2.

4) Switch settings are only programmed during input

power-up restoration.

Setting the DIP Switches

The DIP switches are each labeled with an “ON”
arrow showing the on direction for each of the 8 indi-
vidual switches in each DIP switch (S1 and S2). The
functions of these switches are also labeled and set
as described below:

Pwr Sources

S1

ON

S1

1

2

3

4

5

6

7

8

Head

Pwr Sources

S1

ON

S1

1

2

3

4

5

6

7

8

CONNECTING LN-10 AND DH-10 TO THE FLEXTEC™ 450

CONTROL SETTING

14-PIN CONTROL CABLE K1501-XX

ELECTRODE

FLEXTEC™-450

WIRE FEEDER

LN-10
DH-10

WORK

WELD MODE

WELD TERMINALS

REMOTE/LOCAL

VOLTMETER POLARITY

CV, CV-INNERSHIELD

OFF

REMOTE

PROCESS DEPENDENT