Signal sensing – Linn 500 Solo User Manual

Page 25

Advertising
background image

17

The Klimax contains two power supplies. The small, auxiliary one runs as long

as the mains switch is on and power is present. It powers circuitry which

detects the presence of an audio input signal, and the blue front panel LED.

The signal detector is very sensitive but waits about one second before

powering up the amplifier to be certain the signal was real, not just noise.

When powered up the Klimax will stay on for twenty minutes after the last

signal was detected, then revert to standby. The detection threshold has

been found over many installations to be a good compromise between

sensitivity to low level signals and immunity to noise. However, the residual

hiss level from phono preamplifiers at moderate volume settings can be

enough to trigger the signal sensor. Mute the preamplifier or turn the volume

down after use to prevent this happening. If there is audible hum from the

loudspeakers then you may have enough noise present to trigger the signal

sensor. Always try to eliminate the source of the hum, as this is essential

for a system to sound its best.

Signal sensing

Advertising