K1833-1, -2

K1834-1

K1903-1

A-2

INSTALLATION

PRECISION TIG 375

A-2

ADDITIONAL OUTPUT CAPACITY

Output Current

Range

2Amps DC

to

420Amps AC-DC

*

Type of Output

CC (Constant Current)

AC/DC (GTAW)

Stick (SMAW)

Maximum Open

Circuit Voltage

(STICK AND TIG)

AC/DC OCV: 80

Auxiliary Power

K1903-1, K1833-1, K1833-2

15Amp Circuit Breaker and NEMA 5-15R Duplex

Receptacle for up to:

115VAC 8 Amp Auxiliary Power Receptacle

115VAC 5 Amp weld Switched Cooler Receptacle

K1834-1

5 Amp Circuit Breaker

and grounded 220VAC

Euro(Schuko) receptacle

Height

Width

Depth

Weight

31.0 in.

22.0 in.

26.0 in.

507 lbs.

787 mm

559 mm

660 mm

230 kgs.

49.7 in.

28.0 in.

41.0 in.

751 lbs.

1262 mm

711 mm

1041 mm

341 kgs.

PHYSICAL DIMENSIONS

1

ALSO CALLED

INVERSE TIME" OR "THERMAL/MAGNETIC " CIRCUIT BREAKERS; CIRCUIT BREAKERS WHICH HAVE A DELAY IN TRIPPING ACTION THAT DECREASES AS

THE MAGNITUDE OF CURRENT INCREASES.

*

50/60H

Z

IEC Max. range exceeds 310A.

TEMPERATURE RANGES

OPERATING TEMPERATURE RANGE

-20

°

C to +40

°

C (-04

°

to +104

°

F)

TRANSFORMER INSULATION CLASS 180°C (H)

STORAGE TEMPERATURE RANGE

-40

°

C to +85

°

C (-40

°

to +185

°

F)

For all Stick, DC TIG, and Balanced AC TIG Welding

at 375A/40% Duty Cycle with out Standard Power

Factor Correction Capacitors

Based on the 1999 U.S. National Electrical Code

For Unbalanced AC TIG Welding Above 275 Amps:

350A/40% Duty Cycle, Auto-Balance Penetration with

out Standard Power Factor Correction Capacitors

Based on the 1999 U.S. National Electrical Code

RECOMMENDED INPUT WIRE AND FUSE SIZES

Input

Voltage /

phase/

Frequency

208/1/60

230/1/60

460/1/60

575/1/60

220-230/1/50/60

380-400/1/50/60

415/1/50/60

Input

Ampere

Rating

Rating on

Nameplate

112

102

51

41

119

69

63

Input

Ampere

Rating

139

126

63

50

118

68

62

Type 75°C

Copper

Ground Wire in

Conduit AWG

(IEC) Sizes

6 (13.3 mm2)

6 (13.3 mm2)

8 (8.4 mm2)

10 (5.3mm2)

6 (13.3 mm2)

6 (13.3 mm2)

6 (13.3 mm2)

Type 75°C

Copper

Ground Wire in

Conduit AWG

(IEC) Sizes

6 (13.3 mm2)

6 (13.3 mm2)

8 (8.4 mm2)

8 (8.4 mm2)

6 (13.3 mm2)

6 (13.3 mm2)

6 (13.3 mm2)

Fuse

(Super Lag)

or Breaker

Size

1

150

150

80

50

150

110

110

Fuse

(Super Lag)

or Breaker

Size

1

200

175

80

70

150

110

110

Type 75°C

Copper Wire in

Conduit AWG

(IEC) Sizes

40°C (104°F)

Ambient

3 (26.7 mm2)

3 (26.7 mm2)

6 (13.3mm2)

8 (8.4 mm2)

3 (26.7 mm2)

4 (21.2 mm2)

4 (21.2 mm2)

Type 75°C

Copper Wire in

Conduit AWG

(IEC) Sizes

40°C (104°F)

Ambient

1 (42.4 mm2)

2 (33.6 mm2)

6 (13.3 mm2)

6 (13.3 mm2)

3 (26.7 mm2)

4 (21.2 mm2)

4 (21.2 mm2)

RATED OUTPUT - IEC 60974-1 (K1834-1)

Duty Cycle-Applications

40%

AC/DC Stick / Balance TIG

Unbalance (70% Penetration

#

) AC TIG

60%

AC/DC Stick / Balance TIG

Unbalance (70% Penetration

#

) AC TIG

100%

AC/DC Stick / Balance TIG

Unbalance (70% Penetration

#

) AC TIG

Volts at Rated Amperes

35.0
24.0

34.0
23.0

32.0
21.0

Amps

375
350

350
325

300
275