Blower Operation Guidelines

While in auto operation mode, the blower will turn off and on based on the

temperature of the stove. Auto operation ensures there is sufficient heat

build-up to warm the air being moved by the blower before the blower is

turned on. Likewise, when the stove cools off, the blower is turned off

Blower Operation

The blower can be operated manually or automatically (blower will

turn on when the stove is hot and turn off when the stove is cool).

The rocker switch on the control panel allows you to select between

manual operation or automatic operation as follows (see Figure 23):

MANUAL OPERATION: Turn rocker switch to the “MANU-

AL” position and adjust rheostat knob to the desired speed. The blower

will have to be manually turned “OFF” by rotating the rheostat knob

counterclockwise until it clicks.

AUTO OPERATION: Turn rocker switch to the “AUTO” posi-

tion and the rheostat to the ON position (rotate rheostat knob clockwise

until it clicks). When the stove warms up, the blower will automatically

turn on (adjust rheostat knob to the desired speed setting). When the

stove cools down, the blower will automatically turn off.

Rheostat Operation - The highest blower speed is obtained by turning

the rheostat knob clockwise until it clicks “ON”, then rotate towards

“HIGH” to increase blower speed. Rotate the knob clockwise for a

lower speed. To turn off, continue to rotate the knob counterclockwise

until it clicks “OFF.”

ROOM AIR

BLOWER

SPEED

CONTROL/OFF

TWO POSITION

SWITCH

MANUAL/TEMPERATURE

AUTO-RESET

TEMPERATURE

SWITCH N/O

POWER CORD

3-RED

3-RED

YLW

BLK

WHT

4-GRN

1-BRN

1-BRN

4-GRN

3-RED

NOTE: SWITCH CONDITIONS
GIVEN AT ROOM TEMPERATURE

N/C = NORMALLY CLOSED
N/O = NORMALLY OPEN

= FEMALE DISCONNECT
= MALE DISCONNECT
= STUD CONNECTION

Figure 22 - Wiring Schematic

Figure 23 - Blower Controls

Blower Speed Control

Knob (rheostat)

Manual / Auto

Rocker Switch

to prevent circulating cool air. Depending on the size and intensity of the

fire it may be necessary to adjust the fan speed accordingly to ensure un-

interrupted fan operation. For example a small fire may require a slower

fan speed to keep the heat output by the fan consistent. If the blower is

operated in manual mode, it may be necessary to adjust the blower speed

as the fire begins to burn down and the stove is no longer hot enough to

effectively heat the air moved by the blower. If the air coming from the

blower feels cool, one should either decrease the blower speed or stoke

the fire to build up more heat.