LN-25

B-3

wire speed is set to 400 in/min., a welding procedure
arc voltage of at least 17V would be required to
obtain the 400 in/min. wire feed speed.

WORK CLIP LEAD

IMPORTANT SAFETY NOTE: To avoid possible
electrical shock, do not touch the metal portions of
the LN-25 work lead clip if the power source output
is on. The clip will be electrically “HOT” to work if the
input electrode cable to the LN-25 is electrically
“HOT” even if the gun trigger is off and even if an
internal contactor is used. Care should be taken to
only handle the LN-25 work clip by its non-metal
insulated portions and/or the welding power source
should be turned off before handling the work clip.

The 15 ft work clip lead attached to the front panel
of the LN-25 case must be connected directly to the
work using the spring clip on the end of the lead.

If not connected, the LN-25 will not operate even if
a K431-1 or K624-1 (42V) Remote Output Control
option (refer to Accessories Section) is used.
However, the electrode will still be electrically “HOT”
when the clip lead is disconnected, if K431-1 or
K624-1 (42V) Remote Output Control Option, or
Internal Contactor (K443-1), is not used.

When used with a K460-1 Pulse Power Adapter Kit,
the LN-25 does not need a clip lead.

NOTE: The clip lead also serves as a work sensing
lead for the LN-25 Voltmeter (if installed). If the clip
lead is extended by the user beyond the standard 15
ft. length, the voltmeter reading will be lower than the
actual arc volts due to the LN-25 motor control cur-
rent flowing through the resistance of the extended
lead. To minimize this voltmeter error, the following
minimum lead size is recommended for the
maximum extended lengths shown:

OPERATION

AWG

Maximum Length

#14

25 Ft

#12

50 Ft

#10

100 Ft

#6

200 Ft

REMOTE ARC VOLTAGE CONTROL (OPTIONAL)

This rheostat control allows you to control the power
source output arc voltage level. Refer to K444, K444-
1 and K444-2 Remote Voltage Kits in the
Accessories section.

GAS FITTING (OPTIONAL)

Provides gas output connection to the welding gun
for the GMAW process. Refer to K430-1 Gas
Solenoid Kit in the Accessories Section.

GAS POST PRE-FLOW TIMERS (OPTIONAL)

Allows for variable adjustment of gas pre-flow &
post-flow at the start and end of the weld. Refer to
K434-1 Gas Flow Timer Kit in Accessories Section.

WARNING