A-3

INSTALLATION

MAGNUM® & MAGNUM® PRO CURVE 200 GUNS

A-3

CONTACT TIP AND GAS NOzzLE INSTAL-
LATION

a. Choose the correct size contact tip for the elec-

trode being used (wire size is stenciled on the
side of the contact tip) and screw it snugly into the
gas diffuser.

b. Be sure the nozzle insulator is fully screwed onto the

gas diffuser and does not block the gas holes in the
diffuser.

c.

Slip the appropriate gas nozzle onto the nozzle
insulator. Either a .62 inch (15.9 mm) or .50” (12.7 mm
I.D. slip-on gas nozzle may be used and should
be selected based on the welding application.

Choose the gas nozzle as appropriate for the
GMAW process to be used. Typically, the contact
tip end should be flush to .12 inch (3.1 mm)
extended for the short-circuiting transfer process
and .12 inch (3.1 mm) recessed for spray transfer.
For the Outershield (FCAW) process, 1/4 inch (6.3
mm) recess is recommended.

SAFETY PRECAUTIONS

ELECTRIC SHOCK CAN KILL.

• Do not touch electrically live parts

such as output terminals or inter-
nal wiring.

---------------------------------------------------------------------

WARNING

CONNECTION TO FEEDER

Connection to Lincoln Feeders

Gun cable assemblies which were assembled with a
K466-1 Connector Kit will connect easily to any
Lincoln LN-7, LN-8, LN-9, SP200 or LN-25 feeder.

a. Check that the drive roll(s) and feeder guide tubes

are appropriate for the electrode size being used.

b. Fully push the brass connector end of the gun

cable into the conductor block on the outgoing side
of the feeder wire drive. Secure the cable using the
hand screw or set screw in the conductor block.

c. Insert the control cable plug from the feeder trigger

circuit into the mating socket on the feeder end
cable handle (See K466-1connector kit installation
to gun cable in this section).

d. Slide the free end of the flexible hose onto the

barbed gas fitting on the front of the Lincoln feeder
(See K466-1 connector kit installation to gun cable in
this section) Move the corresponding tubing clamp
down near the end of the tube to assure a good
gas seal

9 / 16” (14.3mm)

LINER TRIM

LENGTH

GUN TUBE ASSEMBLY

GUN HANDLE

COLLAR ASSEMBLY

FEEDER END CABLE HANDLE

SET SCREW

GAS VENTED HOLE

NOZZLE ASSEMBLY

CONTACT TIP

DIFFUSER

LINER ASSEMBLY (LINER BUSHING TO BE SEATED

TIGHT AGAINST BRASS CABLE CONNECTOR)

INSULATOR

9 / 16” (14.3mm)

LINER TRIM
LENGTH

GUN TUBE ASSEMBLY

GUN HANDLE

COLLAR ASSEMBLY

FEEDER END CABLE HANDLE

SET SCREW

GAS VENTED HOLE

NOZZLE ASSEMBLY

CONTACT TIP

DIFFUSER

LINER ASSEMBLY (LINER BUSHING TO BE SEATED
TIGHT AGAINST BRASS CABLE CONNECTOR)

INSULATOR

FIGURE A.2