2 physical and environmental specifications, 1 electrical characteristics, 2 thermal and atmospheric characteristics – LSI SATA 150 User Manual

Page 38: Physical and environmental specifications, Electrical characteristics, Thermal and atmospheric characteristics, Maximum power requirements

Advertising
background image

3-8

SATA 150 Storage Adapter Characteristics

Copyright © 2002–2006 by LSI Logic Corporation. All rights reserved.

3.2

Physical and Environmental Specifications

The design and implementation of the Serial ATA storage adapters
minimizes electromagnetic emissions, susceptibility to radio frequency
energy, and the effects of electrostatic discharge. The board carries the
CE mark, C-Tick mark, FCC Self-Certification logo, Canadian
Compliance Statement, Korean MIC, Taiwan BSMI, and Japan VCCI,
and it meets the requirements of CISPR Class B.

3.2.1

Electrical Characteristics

Table 3.5

lists the maximum power requirements for the MegaRAID SATA

150 storage adapters under normal operation.

3.2.2

Thermal and Atmospheric Characteristics

The atmospheric characteristics for the MegaRAID SATA 150 storage
adapters are:

Temperature range: 0 °C to 40 °C with BBU; 0 °C to 45 °C without
BBU (dry bulb)

Relative humidity range: 20% to 80% noncondensing

Maximum dew point temperature: 32 °C

Table 3.5

Maximum Power Requirements

Host Adapter

PCI/PCI-X +5.0 V PCI/PCI-X +3.3 V Power

Over the Operating
Range

SATA 150-6

1

(load sharing enabled)

0.85 A

1.29 A

11 W

0 °C to 40 °C with BBU
0 °C to 45 °C without
BBU

SATA 150-6

1

(load sharing disabled)

1.63 A

0 A

SATA 150-4

1.5 A

0 A

7.6 W

0 °C to 45 °C

SATA 150-2

0.35 A

N/A

1.77 W

0 °C to 45 °C

1. The total power for the SATA 150-6 takes into consideration the charging of the BBU from the +12 V

and the on-board regulator efficiencies.

Advertising